    a/c not cooling after replaced fan motor
    I recently replaced a condenser fan motor. New motor works great. However, no cold air. I've noticed while outside unit running the fan will turn off for a fraction of a second and then back on. Is this a compressor problem now? A maintenance tech at the factory I work at suggested "jump starting" the compressor with a larger capacitor and then replacing normal cap. Is that a load? Thanks in advance.
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Aug 21, 2008, 06:36 PM
    (((I work at suggested "jump starting" the compressor with a larger capacitor .)))
    I wouldn`t advise that,, you could try replacing the capactor,, but with a exact match to the one you have,the new motor you replaced should have a new seporate capactor all to its self
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #3

    Aug 21, 2008, 06:54 PM
    This momentary slowing of the fan motor may be the compressor trying to start, check your capacitor for the compressor, if bad relpace it . A start booster capacitor can be added to help it start if after replacing the run capacitor and it still won't start. Good luck, Mike
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #4

    Aug 21, 2008, 07:22 PM
    If the A/C system is kicking off and then on (compressor and fan motor) I would say a low pressure or high pressure switch is locking it out. Low pressure switch= low air flow, low on refrigerant charge, restricted metering device at evaporator coil and so on. High pressure switch= dirty condenser coil, over charged, condenser fan motor not running or running backwards or restricted metering device and so on.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Fan runs five munites and shuts off I have replaced run cap & motor [ 17 Answers ]

I have a york unit replaced run cap and fan motor the blade is in the right position the fan motor is oem and run cap matches fan motor spec the ac unit comes on runs 5 minutes and fan shuts off and the fan is not hot to touch. What could it be?

Condenser motor replaced still not working #2 [ 1 Answers ]

Wiring looks good. Does it matter if capcitor is touching metal ? We had no way to attach the new capiter. The old capiter with 3 wires is enclosed in plastic tube, so we did not remove it, just bypassed it. New capiter has 2 wires, instead of 3. When we unplug the new capitor, fan still...

Condenser motor replaced still not working [ 1 Answers ]

Hello, Monday, a/c condenser fan was making loud noise and within an hour of us noticing this, The condenser fan was froze up We replaced the condenser motor and capacitor . It appeared to be working fine for about an hour after new condenser motor and capacitor was in. House temp went...

Ice maker motor module replaced [ 5 Answers ]

I just replaced the motor module on my automatic ice maker and was wondering if anyone here knows how long it takes to run its cycle and begin filling the tray with water to start a new batch. Thanks.

Replaced Outdoor Fan motor, now entire unit does not run [ 3 Answers ]

I have a five year old 2 ton A/C system installed in a small house that is rarely used. When system turned on, compressor would start and indoor fan blower would run, but outdoor fan would not operate. Fan blades were frozen. Replaced outdoor fan motor, including adding a new separate capacitor...


View more questions Search