Ask Experts Questions for FREE Help !
Ask
    somisborn's Avatar
    somisborn Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 18, 2011, 06:29 PM
    Bryant furnace code 45 355bav?
    Tried changing the board, still flashing code 45. Will changing the gas valve help ?
    JonesHVAC's Avatar
    JonesHVAC Posts: 173, Reputation: 12
    Junior Member
     
    #2

    Oct 18, 2011, 08:19 PM
    This is a control circuitry lockout code that means one of the following three: Flame Sensor failure, Gas Valve relay stuck open, and software check error. Turn the thermostat to off --> cut power to furnace for 2 minutes and then turn back on. Have your spouse turn the thermostat back on and observe the sequence of operation before the fault re-appears so you can post it back to us. Thank you.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Bryant furnace showing code 12-blower on after power up. Furnace won't start. Why? [ 0 Answers ]

Blower motor on all the time. No heat from furnace. Why?

Bryant furnace error code 31 [ 3 Answers ]

I have a Bryant 350MAV048100 furnace. It runs for 15 minutes, cycles off and then cycles on and shows an error code 31. I've cleaned out the intake /exhaust lines, but still have the problem.

Bryant furnace code 24 [ 2 Answers ]

First there was a code 24, Ireplaced the fuse, fan works, but not lighting of the flames to produce heat. Any sugestions as to the next step>

Bryant furnace code 33 [ 0 Answers ]

Fan starts up but no heat. Code 33 comes up.. pressure switch problem. Is it the switch or is the sensor line clogged?

Bryant 95 furnace with code 42 error [ 0 Answers ]

Less then a year old. I'm getting an intermittent 42 error. After turning the power back on to the unit it goes through its self check mode and goes back to a constant light, indicating no problems. Then a day or two later 42 again. Both intake and exhaust pipes are clear, new air filter. Any...