    Bryant 330AAV Code 34.every now and then.
    Wanted to know if anyone could help me troubleshoot this problem..
    This furnace will not fire up (every now and then), basically what happens is the igniter lights up, but will shut down after 5 seconds or so. It will do this three times until it goes into lock down, code 34 flashes. I reset power to the unit and it will fire right up no problem. Unit locks out "every now and then", but will restart and fire up as soon as I reset the power to the unit (turning the emergency switch on and off). Followed the troubleshooting guide to no avail. Unit does this once a day, once every other day, once a week, very sporadic, but fires right up after resetting the power. Any suggestions? Thanks.
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #2

    Jan 27, 2008, 10:07 AM
    You may be having a problem with a pressure switch breaking the control circuit during the startup causing it to try and restart until it goes into lockout.Check the tube on the pressure switch and make sure the fitting that the tube is connected to is clear and unobstructed, chech for loose wire connections also, good luck, Mike
    stikittotheman2's Avatar
    stikittotheman2 Posts: 2, Reputation: 1
    New Member
     
    #3

    Feb 10, 2011, 02:46 PM
    I have had this same problem. I cleaned the flame sensor. The ignitor is working. But still a couple of times a day and first thing in the morning it will not ignite.

    I noticed that when it tries to light it would only light a couple of the burners.

    The "Cross-overs" (Slots on the end of the burners) are clogged with dust or residue. So, remove the burners and clean them out. Be careful not to break the ignitor, you may just want to take it out before doing this. I had five burners in my furnace. The burners are the silver tubes where the flame comes out. I just flushed mine out with water and then dried them. Now, my burners light on the first try every time. This is easy to do and will most likely fix your problem.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Bryant 383KAV code 14 - flamesout x4 [ 4 Answers ]

Hello, I have a Bryant gas furnace 383KAV that is 7 years old. Currently the burners come on and then go off after a few seconds. After this happens 4x the furnace delays for 3hours. I thought the flame sensor might be dirty - but I cleaned it some and nothing came off. That didn't help. Filter...

What are Bryant 80 Plus Heater LED Status Code [ 3 Answers ]

What are the status codes that flash on the LED on a system that will not turn on.

Bryant 373LAV060090 [ 1 Answers ]

The inducer blower comes on, both ignitors glow, but I never hear the gas valve open... any suggestions.. thanks in advance (could this be as simple as a bad valve?)

Bryant 310AAV code 23 [ 8 Answers ]

I found your forum after having some issues with my furnace. Age is unknown because I rent and my landlords are out of town. When I went to turn the furnace on tonight, nothing happened. House temp registering 68-69 at thermostat, furnace doesn't kick on when adjusted to 72. Fan will turn...

Bryant furnace does not come on [ 3 Answers ]

We have central AC/Heating with separate Bryant heating and AC units that are controlled from the same thermostat in the house. When I turn the Heat ON and set Temp to way higher than current Temp, the light on the thermostat comes on but the heating unit does not go on... no sound of burners...


View more questions Search