    markj2210's Avatar
    markj2210 Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 4, 2006, 02:12 PM
    Boiler interlocks
    Hi,
    I was wondering if anyone could tell me a little about boiler interlocks?

    I'm into my second year at college (level 2) and am interested in the heating side. At first I thought a boiler interlock was a wiring box but now I know it's a connection between the boiler controls. Trouble is I'm struggling to picture how they are wired.
    For example:
    I have a diagram that shows the cylinder stat and the heating stat being wired to a three port motorized valve (Y plan). Then it shows that the two stats also have a wire to the programmer. Then there is a wire from the motorised valve to the pump and a wire from the pump to the boiler. It made sense that a stat calls for heat, checks with the programmer, and opens the motorised valve which in turn tells the pump to run and the boiler to fire up. I realise that the stats then turn these devices off when they are up to temperature.

    Trouble is, My dad had a plumber in to upgrade his boiler and programmer and I borrowed the manuals to have a look. The boiler manual (glowworm condensing boiler) has a connection for the positive of the room stat from the programmer but no connector labeled for the cylinder stat. The programmer had a connector for the cylinder stat but not for the room stat. How do both stats talk to the boiler to ask for heat.

    Is it that different boiler manufacturers require different wiring to create an 'interlock'.

    I know I'm only a scrote from college but if anyone could at least explain the basics of how a modern setup would look I'll be made up.

    I assume the wiring for an S plan uses a similar principle.

    Thanks for any info.

    Mark
    akhilp73's Avatar
    akhilp73 Posts: 1, Reputation: 1
    New Member
     
    #2

    Dec 16, 2010, 03:29 AM
    Interlocks are some devices or connection system which prevents hazardous conditions in any industrial equipment.
    For boiler, there r many interlocks...
    1.purge interlock-it prevents fuel from being admitted into an unfired furnace...
    2.fan interlock-fuel is shut off on loss of air flow
    3.low fuel supply interlock- fuel is shut off upon loss of fuel suply
    4.loss of flame interlock-all fuel is shut off upon loss of flame in furnace
    5.fan interlock-it stops forced draft upon loss of induced draft fan
    6.low water interlock
    7.high combustible interlock
    cksahu's Avatar
    cksahu Posts: 1, Reputation: 1
    New Member
     
    #3

    Jun 23, 2011, 09:58 AM
    As per boiler manufacturer they have their different design and parameters but some interlocks I am describing you may be useful for you:
    Firstly with ID fan
    Furnace press in positive side
    Drum level
    Dearater level low- low than BFP tripped and than boiler tripped.
    With some drrives Yhanks

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Boiler question [ 10 Answers ]

I live in the state of NY. Does anyone know if it is code to have a low level cutoff when installing a boiler? I am not sure exactly what that is or where it would be installed but I wanted to make sure. I had an estimate by a company and they don't seem like they are going to do this unless I want...

Boiler issues [ 2 Answers ]

I have a water boiler with an external pump and an internal transformer as my heating source, controlled by a Honeywell programmable thermostat. The PROBLEM: #1. When I turn on my heat, the PUMP will NOT START sometimes! At times, it WILL START and run! Sometimes it will start but cycle off after...

Gas boiler furnace [ 3 Answers ]

I have a Burnham gas boiler Series 2A system. I have no idea on how this works, so any light shed on the subject would be great. I guess my real question is about the radiators, vents, ducts, baseboards or whatever you call them with this type of system. Half of my house has SOLID metal baseboard...

Boiler wiring [ 19 Answers ]

Ok, I will try to explain this the best I can with what I saw. I have an old repco boiler with 2 zones and I was wondering if the wiring was correct. The 2 zones are wired into a master control box then goes out to the pump on the boiler and the 2 thermos and another set of wires to another box(not...

Boiler replacement [ 3 Answers ]

I live in Chicago in a 2300 sq ft ranch. The home was built in 1955, and has the original boiler, which was converted from oil to natural gas. Although the boiler is working fine, I wonder about replacing it as the cost of natural gas keeps going up. The efficiency of the new boilers must be far...


View more questions Search