    Blower motor runs constantly
    I have an older heat pump and a/c unit usually works fine today we realized that the blower motor does not shut off.I even turned the thermostat to off but it still runs. Can anyone give me any ideas?Also smelled a little burnt electrical smell when we noticed the blower was not shutting off.
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #2

    Aug 23, 2008, 06:35 PM
    Yep, the contactor to the blower stuck. Needs to be replaced.
    mkrug17's Avatar
    mkrug17 Posts: 2, Reputation: 1
    New Member
     
    #3

    Aug 23, 2008, 06:38 PM
    The blower motor was just replaced a month ago would that have been replaced then?
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #4

    Aug 23, 2008, 07:21 PM
    Nope.
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #5

    Aug 23, 2008, 07:34 PM
    Its true it may just be a stuck blower relay but that will not explain the burnt smell. You may have a electrical short at the heat strips or blower control wires causing the blower to run all the time. A slight ground can make a 230 volt motor run with out tripping the breaker or fuse. Be careful if you investigate. Turn power off to the system first.
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #6

    Aug 23, 2008, 08:25 PM
    Actually it could explain the smell. If the contacts are heating up, the relay itself can smell.
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #7

    Aug 24, 2008, 04:21 PM
    True but in my opinion I have found that less than 5% of the time the burning smell coming from a residential system is not derived from the blower relay.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Goodman blower runs constantly [ 3 Answers ]

I recently purchased a home with a Goodman furnace and had no idea if the furnace worked or not. The thermostat had the wires from the wall cut with no thermostat, so I replaced it. I'm not sure if the thermostat is wired properly... The wires coming from the wall contain 2 wires, red and white....

Blower motor running constantly [ 6 Answers ]

We have an older bryant furnace It heats up but the fan runs on and on there is a switch that says summer fan when its on it runs constant if you switch that off the fan won't blow at all help needed soon thanks Michelle

Blower motor runs slow [ 2 Answers ]

I have a Luxaire Furnace with a/c, blower motor on furnace runs but very slowly, what would cause this, units are about 9 yrs. Old, motor starts slow and stays slow

Blower motor runs constantly with thermostat in Off position [ 2 Answers ]

The original problem was that periodically the blower motor would stop running when cooling which caused the outdoor unit coil/condenser to freeze up. If I cut the unit off, let it melt, turn it back on, it would run fine for a period. That period could be 3 hours or 3 days. After taking a...

No heat, blower runs constantly, carrier gas furnace [ 7 Answers ]

This am we I got up the blower on my carrier series 100 gas furnace (approx 10 years old)was running and blowing out cold air. Even with the thermostat turned to off the blower runs constantly. The only way to stop the blower from running is to turn the switch on the side of the furnace to off or...


View more questions Search