Ask Experts Questions for FREE Help !
Ask
    hnewhard's Avatar
    hnewhard Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 30, 2009, 08:29 AM
    Baseboard heaters
    Can you daisy chain baseboard heaters and use one baseboard mounted T-stat.

    Thanks Harry
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Oct 30, 2009, 10:59 AM
    Yes and no. It really depends upon the amount of amperage the control you are using can take care of and the amount of amperage the heaters you plan on combining produce in amperage load. I would never go over 80% any way since it is not good to tax a control at full value.
    dac122's Avatar
    dac122 Posts: 463, Reputation: 17
    Full Member
     
    #3

    Oct 31, 2009, 07:02 PM

    Yup, just like hvac said: size the circuit and tstat right and you can daisy chain more than one. I have one circuit with up to 3: 1KW, 1.5KW and 1.85KW.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Baseboard heaters not getting hot [ 1 Answers ]

My apartment has five Marley C Model TA2ANWC, double thermostat, 22 amps 120-277 baseboard heaters. All are wired with 10-2 AWG. One double circuit breaker is marked with two 60s and the three units work fine. The other double circuit breaker is marked with two 50s and operates the other...

New to baseboard heaters [ 24 Answers ]

Hello; I need a lot of electrical help/advice. I am trying to install an electrical baseboard heater in a basement room (15'X10'). My friend helped me already do the following: Run the conduit and electrical box for thermostat Pull all the wires Mounted the baseboard heater to the wall We...

Baseboard heaters [ 2 Answers ]

I have some used baseboard heaters I want to install in my basement. 1) They have two wires on the unit itself and four wires on the thermostat, can I assume my power coming in must go to the thermostat first and then to the heater? 2) The four wires on thermostat are labeled L1 & L2 and T1...

Electric baseboard heaters -wiring 1 thermostat to two heaters [ 2 Answers ]

I would like to heat my new garage with electric baseboard heaters. The new garage is 20X24 feet. I would like to use only one 240V #12 2 wire circuit running two heaters at a total of 3800 watts. I plan to use 2 pole 20A breakers and 2c #12 wire. I would like to have both heaters controlled...