    Armstrong SX 80 Furnace will not light at main burners
    This will be our second fall/winter in this house and our Armstrong SX 80 furnace with a Honeywell smartvalve ignition system will not light. The ignition switch will come on, but no gas is being emitted so the main burners will not light. I have seen this before where the sensor is bad after the burners come on, but the burners never come on.

    The main blower goes, I have checked the wires that feed in to the control portion of the Smartvalve, but cannot get any gas to flow.

    Any ideas?
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Oct 10, 2009, 10:40 AM
    May be a silly question,but are you sure the gas is on?, also at the time igniter comes on can you hear a click coming from the gas valve? Indicating that there is power going to the gas valve?
    gogomugo's Avatar
    gogomugo Posts: 2, Reputation: 1
    New Member
     
    #3

    Oct 10, 2009, 10:49 AM
    The gas is on because our water heater is right next to the furnace with the same supply and it is working like a champ, knock on wood. You are right, there is no click coming from the gas valve
    elsie08's Avatar
    elsie08 Posts: 1, Reputation: 1
    New Member
     
    #4

    Apr 15, 2010, 06:07 AM
    We had similar problem. For two winters, the igniter would come on but not the burners. This was intermittent, sometimes the burners would come on fine. This past January it got worse. First time repairman came out, claimed was just dirty and hose to pressure switch clogged. Worked OK for a day, then intermittently working again. Then he said pressure switch bad, so we replaced it. That didn't fix it. Replaced the fan and igniter, on our own, didn't fix. Finally called another company recommended to us, the gas valve was not opening all the way, enough for the igniter but not enough for the burners. Replaced ($500) and working perfectly now. Finally.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Main burners on furnace do no ignite [ 8 Answers ]

I have a bryant furnace, model 398. The main burners do not light after the pilot light ignites. I have cleaned the blower motor and everything else I can. Everything looks and sounds good, but the main burners are not getting any gas to them and lighting. Its getting cold in here and need some...

Goodman furnace HSI does not glow, burners never light [ 3 Answers ]

I have a Goodman gas-forced air furnace, about 10 years old. I have power to the main control panel (part# 18099-13) and gas is "on". In the furnace sequence posted by sticky, I am having problems at the step where the hot surface ignitor "glows" to light the burners. All other steps, such as the...

Goodman pilot light on but furnace burners will not come on? [ 4 Answers ]

We have a Goodman furance that will not produce heat. The pilot light is on, the gas is released, but the burners will not kick in. Do you have any idea what is causing this problem.:confused: Scott's Chicago

Armstrong ultra sx 80 furnace no pilot light [ 3 Answers ]

We've had a problem the last 2 winters with our furnace, always fixed but last night the furnace stopped working. We checked and there was no pilot light. Actually in this model we don't even know where we would light it. Someone told me it might be the thermo couple but I am in need of another...

Main burners on my carrier furnace not lighting [ 1 Answers ]

I have a carrier natural gas furnace, model no. 58es080-30. The pilot light ignites, then you can hear a clicking noise, after about 15-20 seconds the blower fan starts up but the main burners are not lit. The furnace has acted like it's been having trouble igniting in the past few weeks, seems...


View more questions Search