    Amana furnace short cycling
    The induction motor comes on then the heat it's stay's on for two mines then cut off it short cycling all nights. Is this a bad pressue switch ,or abad board
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jan 24, 2008, 06:12 PM
    Could be dirty flame sensor
    Water in feed tube for pressure switch.
    Dirty air filter
    Out of calibration high limit control.
    Plugged or restricted exhaust tube or flue
    Thermostat may need heat anticipator adjustment
    metzgr3257's Avatar
    metzgr3257 Posts: 1, Reputation: 1
    New Member
     
    #3

    Feb 15, 2010, 04:50 PM

    I have a gibson, high efficiencey gas furnace that is short cycling even when the thermostat is not calling for heat. I have the t-stat set for 51 degrees in a vacant house and the room temperature is 55 degrees and the furnace is short cycling nonstop.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Well motor -Short Cycling [ 13 Answers ]

Old houses... great aren't they? I have a new dilema. Seems as though the well motor is beginning to short cycle during a shower or if the washer is running. I would suspect the pressure switch, however I do not know which side is the low side and which is the high side, nor do I know where to...

Furnace cycling [ 2 Answers ]

My newer energy efficient furnace cycles every 10 minutes about, I have a new one story home that is very well insulated.

Furnace cycling [ 1 Answers ]

I have a Trane gas furnace w/no standing pilot it's electronic. Anyway when the t-stat calls for heat it will fire up and the shut of within 5 secs. It will do this approx. 4 times before it will eventually lock itself out and the blower will continue to run not ever reaching setpoint. I know...

WELL Pump is short cycling on and off [ 3 Answers ]

I have a well pump on a 40 60 pressure switch. When a tap is open the pump kicks on and off every 30 seconds or so. The pressure tank is small probably 40gal? When the water is flowing you can watch the pressure gauge drop in pressure, and then watch as it moves up when the pump kick in for 20...

Heil furnace short cycling of burner [ 1 Answers ]

My 1983 heil model NUGK075DG01, natural gas, forced air furnace is running but only heats the house to 67 degrees no matter how high I set the temp, the fan continuously runs (in auto on thermostat) and the burner will cycle for 3-4 min. then shut-off for 10 min.. I have powered down and back-on,...


View more questions Search