Ask Experts Questions for FREE Help !
Ask
    CGM91's Avatar
    CGM91 Posts: 70, Reputation: 2
    Junior Member
     
    #1

    Oct 29, 2009, 02:46 PM
    I am a bit confused how a Refrigeration Cycle works?
    This is a question I have and I am not sure how I am supposed to figure Low side saturation temperature, total superheat exiting the evaporator etc..

    R-22 - Refrigerant
    Low side pressure = 68.5 psig
    High side pressure = 210.8 psig
    Discharge line temp @ compressor = 150 deg F
    Liquid line temp = 90 deg f
    Suction line exiting the evaporator = 52 deg F
    Suction line temperature entering the compressor = 65 deg f
    Identify all components and appropriate lines example (suction line) on this diagram, also
    show where pressures and temperatures should be taken.




    Low side saturation temperature __________ deg f
    Total superheat exiting the evaporator _________ deg f
    Total superheat entering the compressor _________ deg F
    Total superheat exiting the compressor _________ deg F
    High side saturation temperature _________ deg F
    Total subcooling exiting the condenser ________ deg F


    ---

    If someone could help me out I would be VERY thankful,

    Thanks.

    - Chris
    CGM91's Avatar
    CGM91 Posts: 70, Reputation: 2
    Junior Member
     
    #2

    Oct 29, 2009, 02:53 PM
    PT Chart;



Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Washing machine only works in spin cycle [ 4 Answers ]

I have an old Kenmore 80 Washer and nothing works, but the spin-cycle. Many posts say that it's the Water inlet valve, but I don't want to spend $30-$40 to change it if it's not the right part. If it's the Water inlet valve, I figured if I filled the washer up with water the washing machine...

Rheem Criterion II--heat cycle works, then shuts down [ 2 Answers ]

Hi- I'm having a problem with my gas furnace and don't know where to start to find out what it might be. When the thermostat calls for heat, the draft inducer kicks on, the ignitor glows, the gas starts and burns for a short time and then shuts off. It tries this whole cycle again, with the same...

My heat pump AC works but not on heating cycle [ 2 Answers ]

I live in a 2-story house in AZ and there are 2 Lennox (sic?) heat/AC pumps, one for each floor... it has 2 Honeywell TH8000 thermostats. Last winter there wasn't any problems but tonight it started getting cold so I turned it from cool setting to heat, I can hear relays in the TS click and it says...

Confused about cycle [ 5 Answers ]

Hello every one out there(especially to those with helpful comments)! I'm a twenty four year old female with no kids, so I am fairly new at this, but my concern is my period, it is February the 3rd 2007, and the last time I had a period is December 14-22nd of 2006. I had protected intercourse...


View more questions Search