    RichINO47's Avatar
    RichINO47 Posts: 1, Reputation: 1
    New Member
     
    #1

    Feb 7, 2007, 06:28 PM
    Altering Oil Burner Transformer wiring for continuous run
    On Monday I had the oil burner service man come in and fix a problem where the oil burner kept shutting down every 10 hours or so for 2 days. He cleaned the nozzle and the system worked fine. This morning Wednesday (2 days later) we received an oil delivery and after an hour or more we had no heat. The tech is saying that sometimes the oil burners have trouble lighting the fuel when it first comes out of the truck because it's so cold ( is this true? I've never heard this before or ever had this as a problem?). The way he explains it, the transformer generates a spark that ignites the fuel. He says mine is wired to generate the spark only for a set amount of time and then go off. He rewired it so the spark stays on. Now I'm a fire freak so this has got me real nervous. He claims that this is not a fire hazard and is an acceptable method for fuel burners. I've dealt with this company for over 23 years and never had a problem but it doesn't pay to be too slack. Does anyone know if this is legit? Or where I can get information on it? The last thing I need is to have the house go boom in the middle of the night, especially with me in it! Nor do I need something else to go wrong because the transformer is wired incorrectly. :eek:

    Thanks for you help,
    Rich
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Feb 8, 2007, 12:12 AM
    The cold oil is BS. Your burner should be constant ignition already while the burner is working so I have no idea what the service man is talking about. If it was setup for intermitent ignition it would not make a difference as to why your burner went off. The cad cell detector turns the burner off if there is a lack of flame. Did they replace the oil filter during the service? One other thing. You might have lost your prime if you ran out of oil since you had to put 300 gallon in it. If you continue to have problems call a different company.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Oil furnace, Burner cuts out [ 4 Answers ]

Ok, my original post was over a noisy draft regulator. Since then I have determined the cause of the regulator banging was the burner going out. This only occurs for a fraction of a second, just little pulses. I changed my in-line fuel filter and my burner nozzle. When I remove the inspection cover...

Wiring 12 volt transformer [ 1 Answers ]

I have recently installed some 12 volt miniature lights in home. I have them working now but began wondering about how I have the 12 volt transformer wired. The lights are on a switch and I have the transformer in the line before the switch. Thus I have power at the transformer all the time. Is...

Oil burner Blower cycling on and off [ 2 Answers ]

Just finished with a new second floor addition. Upgraded to two zone heating from single zone. When heat comes on after expected delay for temp to rise the blower comes on for fifteen seconds then kicks off and comes on again in about two or three minutes, and kicks off again in fifteen seconds, on...

Oil Burner Furnace [ 1 Answers ]

The problem goes like this. Thermostat calls for heat, burner starts and runs for a minute or so and shuts off. After burner shuts off, the blower starts and the burner starts again until the thermostat reaches temp and the burner shuts off blower contiues to run until the low temp limit is...

Transformer wiring [ 18 Answers ]

I have a Payne furnace that had a Intermatic wall timer connected to it. The timer was causing the furnace to come on at various times and sometimes just the blower (it'll run all night). If I hit the on/off button on the timer, it'll disable it for 24 hours. I attempted to disable the timer...


View more questions Search