    Air conditioning system, TRV equalizing line icing
    It's a Urea Fertilizer Bulkstore-Dehumidifier system.Its a condenser cooling, Chilled water ACU system type Carrier Semi Hermatic compressor 2 in nos system in one chiller system (combine chiller).System was shut down due to malfunction of the TRV suspected. Ordered to change the filter-drier and renew the TRV welded type TRAE30HW100 6Amps. For R 22 gas system. Renewed as ordered. Purged the affected area.Charged in more gas,and run system and continue charging gas for about 20 minutes. The LP 60 psi, HP 225 psi and Load was 38.5 Amps. At this juncture the TRV equalizing line icing (liquid flow) to retun line.Then the load was 34 amps, LP drop to 38 psi.HP I did not read.And I cannot continue charging gas at 35 amps. Can I know the cause and remedy to this.
    My own suggestion is, since it is a new TRV, I might have to adjust, screw down the TRV adjusting screw a little to allow more gas to flow through the line. Such that the liquid line valve will close in. Tks, Allan.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Dec 31, 2009, 12:50 PM
    My own suggestion is, since it is a new TRV, I might have to adjust, screw down the TRV adjusting screw a little to allow more gas to flow through the line. Such that the liquid line valve will close in. Tks, Allan.

    I agree follow your own suggestion since all valves of that type need to be adjusted properly. The icing is always a dead give away unless there is a restriction OR non-condensibles in the system. When you said purge I am sure you meant vac.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Air conditioning system [ 2 Answers ]

What are the technical parameters needs to be considered while selection of chiller?:p

Air conditioning system [ 1 Answers ]

Hi all, I am new to this site... Could some one help me for the following What is mean by hot gas by-pass? Why hot gas bypass is necessary in a/c System?

Air conditioning system [ 1 Answers ]

How will u calculate water velocity (m/s)in condenser unit?

Air conditioning system [ 1 Answers ]

What is mean by condenser approach tempreture?


View more questions Search