Ask Experts Questions for FREE Help !
Ask
    engjon510's Avatar
    engjon510 Posts: 2, Reputation: 1
    New Member
     
    #1

    Jun 7, 2009, 02:58 PM
    AC Wiring issue (Carrier Weathermaker 8000 24v error code)
    I have a Carrier Weathermaker 8000 furnace, which I just had the Control Board changed. Tried turning on the AC and nothing. Get the 24 error code which is 24 volt short. Keeps blowing the 3 amp fuse. Have replaced the wires from the Condenser to the control board. If I remove the wires from the board and turn on the heat, it runs. Turn on the AC with the wires off, fuse blows. Any help would be greatly appreciated!
    engjon510's Avatar
    engjon510 Posts: 2, Reputation: 1
    New Member
     
    #2

    Jun 7, 2009, 03:01 PM

    Oh and I have done a visual on all the control wires and do not see a short.
    Joshdta's Avatar
    Joshdta Posts: 2,549, Reputation: 45
    Ultra Member
     
    #3

    Jun 7, 2009, 04:29 PM

    Fuse blows with the wire unhooked at the ac unit?
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #4

    Jun 7, 2009, 06:08 PM

    If fuse blows with wires disconnected from ac unit, it sounds like you have a short in thermostat wires from thermostat to board on furnace. Or, new board was inproperly wired.
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #5

    Jun 7, 2009, 07:28 PM
    Check for a low voltage short inside the A/C unit: Wires going to the high pressure or low pressure switch. A coil that is bad on the contactor will give the same symptom.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Error Codes for a Carrier Weathermaker 8000 [ 7 Answers ]

Can I find the error codes to my furnace online? I have a Carrier Weathermaker 8000 model # 58wav070-12.

Carrier Weathermaker 8000 keeps getting error 34 [ 8 Answers ]

I keep getting an error 34 when I try to start my weathermaker 8000, I think the problem is low inlet gas pressure because the gas comes on after the click. I gently fanned the gas towards the igniter and it worked. If I don't do this it cuts off after four tries with out igniting. Like a said,...

Error code 14 - Carrier Weathermaker 8000 [ 4 Answers ]

I've cleaned the flame sensor after days of ups and downs into my attic. I'm wondering if there is a reset switch that I need to trip. My steps were 1) unplug the power source, 2) remove covers, 3) turn off gas control switch 4) clean flame sensor with steel wool and 5) reverse through the...

Carrier Weathermaker 8000 Error Code 24 [ 1 Answers ]

I have a Carrier 8000 Weathermaker (model # 58WAV091-16) that is displying error code 24. Any idea what this is (24 SECONDARY VOLTAGE FUSE IS OPEN Check for: - Short circuit in secondary voltage (24V) wiring and how I can fix it?

Carrier Weathermaker 8000 Trouble Code [ 2 Answers ]

I have a carrier Weathermaker 8000. Started up furnace and forgot to remove baffle. Now have trouble code 33 and have to manually reset. How do I accomplish this?


View more questions Search