    RJB61 Posts: 1, Reputation: 1
    New Member
     
    #1

    Jun 18, 2012, 10:28 AM
    AC keeps blowing system fuse.
    System is 11 years old
    I have a Honeywell Chronotherm IV Plus T8601D2019 Tstat. (A/C only)
    Condenser is a Trane XL1200. 
    Unit is a Trane XV80
    5 wires to Tstat:
    Blue = C
    Red = R
    White = W
    Yellow = Y
    Green = G

    Unit has performed solid up to this point. 

    Yesterday I changed the filter element (which I do religiously every 3 months). Same brand and model I have used for about 5 years. Unit ran on-and-off for 10 hours (light usage) then stopped. I noticed the screen was blank on Tstat. Checked indoor unit and it was humming, but flashing light out.  Checked unit panel and found 5A ATO fuse blown on board. Replaced and Tstat powered.  Soon as it sent a message to start AC (snowflake) it clicked and blew fuse.  Checked for obvious loose wires, checked breaker, checked fuses on condenser. Nothing found.  Installed new fuse and repeat. Blew again the same way. 

    With that clicking sound, My thought was a short.  Not sure whether the click comes from the main unit or the Tstat. 

    Suggestions on how to efficiently proceed would be appreciated. 

    Thanks

    Richard

Check out some similar questions!

E fuse in Carrier gas furnace keeps blowing. Should a different fuse be used? [ 1 Answers ]

E fuse in Carrier gas furnace, model 58MCB, keeps blowing. Should a different fuse be used, or is the problem likely in a component.

Fuse Keeps Blowing [ 1 Answers ]

I have an HK42FZ004 cercuit board. The fuse started blowing every so often after I resoldered two resistors with cracked solders. The fuse noe blows as soon as I replace it and turn on the power. I cannot figure out where the problem is. Please help

Fuse keep blowing [ 1 Answers ]

I am not sure what is happening, We have two units the upstairs is running just fine. Now the downstairs keep blowing the fuse in the furnace. What it does is that it will let the fan run but when I reduce the temp. so the a/c will come on it blow the fuse. Thanks, George

A/C keeps blowing fuse [ 11 Answers ]

I had an earlier post about neither the furnace or a/c working... well the problem was a blown fuse, and I have no idea why I didn't find it earlier. Anyway, I replaced the fuse and the furnace heat now works, but when I go to the a/c, the fuse blows every time. My furnace takes a little 5 amp buss...

Keep blowing fuse [ 1 Answers ]

1998 Dodge Ram, been sitting for about a week, went to turn on windshield wipers and they didn't work. Check the fuse and it was blown. Changed fuse and as soon as I put it in the fuse blows. Did this several times and no luck. ANY IDEAS! THANKS,


View more questions Search
 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.