Ask Experts Questions for FREE Help !
Ask
    emhca's Avatar
    emhca Posts: 1, Reputation: 1
    New Member
     
    #1

    Jun 5, 2007, 07:23 AM
    AC Compressor unit will not shut off
    Here is the problem. Lets say it is 80 degrees. I turn the central air conditioner on, set at 78 degrees. The house cools down to 78 degrees. The thermostat appears to shut the blower (from the furnace) off and acts like it everything is shut off. However, the outdoor AC unit continues to run and will continue to run until someone turns the circuit breaker switch off. The unit (and thermostat) is about ten years old and nothing on the system has been replaced recently.

    Anyone have any suggestions as to what the problem is?
    JackT's Avatar
    JackT Posts: 260, Reputation: 19
    Full Member
     
    #2

    Jun 5, 2007, 01:14 PM
    I'd start by checking the contactor in your outside condensing unit. If possible, next time it happens disconnect one of the small 24 volt lines that goes to the outside condensing unit. If you unhook the wire and the unit still keeps running, your contactor most likely has bad contacts that are sticking closed.
    leola's Avatar
    leola Posts: 2, Reputation: 1
    New Member
     
    #3

    Aug 5, 2010, 12:21 AM
    Air conditioner continues to run,but not cooling the house. What could be possible causes?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Heat pump condensing unit will not shut off [ 4 Answers ]

My heat pump condensing unit has been running for several hours now without shutting off. It is blowing out cool air. When I turn unit off manually and turn back on, you can feel the heat for a few minutes and then it goes back to cool. Please help...

Outside unit doesn't come on when thermostat turns inside unit on so no heat? [ 1 Answers ]

My thermostat will trip my heater to turn on. The inside blower turns on but the outside unit doesn't turn on. I can get it to go by turnign off the unit at the thermostat and waiting a minute. I turn it on and off until I hear the outside unit turn on. The problem is when the Thermostat turns if...

A/C unit won't come on, compressor OR blower [ 2 Answers ]

Hi, I am new to this site, so I am not sure how this works. I woke up early this morning because I was hot, only to find out that my upstairs HVAC unit was not blowing air. I went into the attic, and the compressor is not working, so I went outside, and the blower isn't working either. I was...

Size of ac unit needed to match a carrrier heating unit [ 3 Answers ]

I had a Carrier natural gas heating unit installed in 2003. Model number 58STA/STX 070 Catalog number 535-80105. My ac unit has gone out and the company I bought the heating unit from has gone out of business. What size ac unit will match the heating unit? Thanks so much!:cool:

Replacement of electric unit with gas unit in mobile home [ 2 Answers ]

#1 Dec 27, 2006, 10:32 PM vcavina New Member Join Date: Dec 2006 Location: California Posts: 7 Electrical wall heater in single wide mobile home