    3 ton compressor in 4 ton condenser
    I have come across a lennox 4 ton condenser hpxa16-048-230-01. This is 410a heat pump system. I would like to replace the compressor to 3 ton r-22. Is this feasible? Would I need to change reversing valve?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Mar 13, 2009, 08:18 PM
    It could be done but you better know exactly what you are doing. The real question is why go to all the trouble?
    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #3

    Mar 14, 2009, 09:38 AM
    Quote Originally Posted by hvac1000 View Post
    It could be done but you better know exactly what you are doing. The real question is why go to all the trouble?
    Indeed, what is your objective here? This project, as described, has great potential... for failure.
    Mikie D's Avatar
    Mikie D Posts: 45, Reputation: 1
    Junior Member
     
    #4

    Mar 14, 2009, 04:14 PM

    You would have to flush system with R11 and the reversing valve has to be changed and the expansion valve has to be changed or orfice to be changed and yes it will work ,you will have to play with fan speeds to get a 18-20 degree drop but you will never get the efficiency of 410A. Mikie D.
    daisymay58's Avatar
    daisymay58 Posts: 3, Reputation: 1
    New Member
     
    #5

    Mar 14, 2009, 04:44 PM
    Call my friend Lou he can answer any of those type of questions 215-989-0168

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Outside AC condensor/compressor unit not coming on at all [ 7 Answers ]

My outside central AC condensor/compressor unit (a Lennox) is not turning on at all. When I switch on the thermostat, the blower in the basement starts running and air is coming through the vents, but the outside unit is not turning on at all, so there is no cool air. Is the likely problem a...

Condenser fan [ 1 Answers ]

My ac is a goodman cpkj30-1ab. The condenser fan comes on every once in a while. I put a high velocity fan on top so I could keep using the ac. It looks to have 3 capacitors on it. One says hard start. The other is tall and round and the other is short and oval. My question is which is the...

Condenser Fan [ 3 Answers ]

My sons house took a power hit (off and on) about three times from a storm. Now the fan does not work on the condenser. Any ideals of what the problem might be?

Condenser Fan [ 1 Answers ]

Condenser fan motor , took a power hit during a storm and now fan will not come on , any ideals why?:mad:

AC condenser compressor and fan not working [ 1 Answers ]

The inside blower motor works, just the outside unit will not turn on. Everything is fairly new. I replaced the capacitor, contactor, and the Hard Start Kit. Everything looked fine. Niether compressor nor fan will turn on by itself. I pushed on the single pole contactor and the unit jumps to life...


View more questions Search