    t56tr's Avatar
    t56tr Posts: 25, Reputation: 1
    New Member
     
    #1

    Nov 29, 2009, 09:09 PM
    2nd floor rads always have some air in them
    Hello,

    I have a house built in '29. Hot water boiler with cast iron rads. Boiler is a 1990 peerles, gas.

    My 2nd floor rads always have a little bit of air in them- all of them. For example, if I check them every couple of weeks they will bleed out a little air when I crack the bleeder.

    Downstairs never has any air, just water when you open the bleeders.

    Is this normal?

    PS the 2nd floor rads seem to work OK despite the air.

    The boiler has a street water line feeding a regulator, a green expansion tank, and a pressure valve. Operating pressure is about 10lbs according to gauge.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Nov 29, 2009, 09:33 PM
    It could be normal since it takes a long time to cook out the intrained air that is present in water. Heating the water also helps to release the same air as mentioned before. All air in your system usually ends at the highest point that is whay I always put an auto vent at the highest point to have a automatic air eliminator .

    One last item the air could also come from your auto water feeder since the incoming cold water always has some air in it.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Two-zone EWC-ST-2D gas hot air and air conditioning furnace [ 0 Answers ]

I have a two-zone EWC-ST-2D gas hot air and air conditioning furnace. With two RITETEMP 8050 thermostat controls mail level and the other is upstairs. Is the C wire the other side of the 24VAC heating transformer because the 8050 can run on 24VAC series power. 24VAC ONLY. Power for the...

Can my 2nd Floor support a bathtub [ 4 Answers ]

Hi All, I am planning on installing a tub or shower unit on my second floor bathroom. I have just moved my washer/dryer to another location make room. The last owner cut part of the beam below the dryer so he could vent it. Now I am worried it may not support a tub. Any thoughts?

2nd time on F1 FICA withholding [ 2 Answers ]

Hi My situation: Israeli Citizen, have an SSN since August 2002. Aug 2002 - June 2006: F1 for undergrad (including 10 months of OPT) June 2006 - July 2008: H1B August 2008-present: F1 for graduate school I am going back to work for the same employer in July 2010. I have the option of...

Ground floor rads not heating top floor are fine [ 1 Answers ]

The ground floor rads do not heat up but the top floor rads are all working fine:

Noisy Pipes & Hot Water System Heating Rads! [ 1 Answers ]

I have 2 problems with my CH system. Firstly when the hot water is turned on there is an awful lot of noise from the pipes. This sounds like a river rushing through the house. I can also hear the pump through the pipes. When I turn the pump down the noise is reduced but is still too noisy. This...


View more questions Search