    May 6, 2007, 06:27 PM
    White rodgers 90-113
    How to wire a relay
    CaptainRich's Avatar
    CaptainRich Posts: 4,492, Reputation: 537
    Cars & Trucks Expert
     
    #2

    May 6, 2007, 07:10 PM
    A relay is simply a mechanical control switch with a low current control switching a high current load. If you hit the key to start your car, the low amperage key switch grounds the solenoid side of the relay and closes the switch side and allows high current flow to the starter. The normal amperage for a starter is relatively high and wouldn't be acceptable flowing through the ignition switch. Now! Having said that, what are you up to?
    ZCCG's Avatar
    ZCCG Posts: 20, Reputation: 2
    New Member
     
    #3

    May 7, 2007, 07:37 AM
    Hazard,
    here is a link and some information that I found online about your relay.
    Read this and it might help you with your problem.

    Make sure that you follow safety procedures.

    Good Luck,
    Cory

    Fan Blower Controls

    Problem: Fan will not come on in the "ON" position or your fan will not come on when you turn the thermostat down in the air conditioning mode.

    Purpose of the Fan Center Relay: The purpose of the fan center relay is to provide low voltage control (24 Volts) of line voltage circuits (110 volts) and can be used to control two-speed blower motors and auxiliary circuits in heating or cooling equipment. Many of the newer furnaces do not have fan center relays, but many of the older furnaces and some new furnaces still do. You would need to look inside your furnace to determine if you have a fan center relay. Some of the relays are attached to a junction box where the power comes into the furnace, and others are located in the blower compartment attached to the blower housing. You might not have the relay that we sell below. Many of the newer furnaces are control by electronic circuit boards.

    Troubleshooting procedure:
    1. Make sure that your furnace switch is "ON" the furnace blower compartment door is on and secure. Move the lever on the thermostat to the "ON" position. The fan blower should come on. If it doesn't then you probably have loose or burnt wires in behind the relay or you may need a new fan relay or circuit board.

    2. Many times wires are either loose or burnt behind the fan center relay. First make sure your furnace power is turned off. Remove the fan center relay and inspect it for loose or burnt wires. Repair wires and reinstall fan center relay. Turn the power to the furnace back "ON." Hopefully you have fixed the problem!

    3. With the furnace on use a multimeter set to AC Volts, to test between terminals "R" and "C." You should get a voltage reading of approximately 24 volts AC. If you do not get any voltage reading, your low voltage transformer might need replacing or you are not getting high voltage to power the transformer. Sometimes furnace manufacturer's connect the furnaces transformer through the limit control so if your furnace over heats or if the limit is stuck open then you will not get power to the transformer. There are quiet a few variables that can occur to cause furnace problems. I believe I have covered the main problems. If you have the fan center relay like we sell below the low voltage transformer is combined with the fan relay. Below we have pictures of the fan center relay with an opportunity for you to purchase. This relay will work on motors up to 3/4 horse power.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

White-Rodgers Thermostat Manuals [ 6 Answers ]

@tkrussell - Re: your sticky about thermostat manuals, here is a link for technical data, including manuals for White-Rodgers thermostats: http://www.white-rodgers.com/wrdhom/common/ptech/ptech_thermo.htm

Troubleshoot white-rodgers 1F86-244 [ 3 Answers ]

Hello... Looking for help here in South Florida. We have a White-Rodgers 1F86-244 thermostat hooked up to a 2 year old Trane air handler (don't have model number handy) that will not engage. We have an error message on display that says "filter" and when trying to engage the AC the snowflake...

Need Wiring help for a White-Rodgers Thermostat [ 2 Answers ]

I have 2 wire (red & White) heat only system. It is steam heat run by gas. Currently I have Honeywell thermostat which uses 3 AA batteries. Thermostat has R, RC, O, W, Y, G terminals. R and RC terminals are connected by a jumper cable. I have Red wire connected to terminal R and white wire...

White-Rodgers thermostat... What does this mean? [ 2 Answers ]

Okay, I'm about to smash this thing up. I fell asleep with the AC turned off earlier and now I wake up and its 77 degrees in here and I'm sweating. So I go turn the AC unit back on, setting it on 75 degrees to start with because I know you aren't supposed to do more than 2 degrees at a time....

Rplacing Weathertron thermostat with White Rodgers [ 3 Answers ]

Hello, I have a heat pump with auxiliary electric heat controlled by a Trane Weathertron thermostat. I am attempting to upgrade the thermostat with a programmable White -Rodgers(1F85-277)heat pump thermostat.I want to verify the correct wiring hookup for White-Rodgers Thermostat to the current...


View more questions Search