    What spec wire do I need to use?
    I am planning to run 240 volt service to a small shop about 50 feet behind my house through a 50 amp breaker in the main panel in my house. What wire should I use?
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #2

    Aug 1, 2014, 06:06 PM
    Are you thinking conduit or direct bury? Makes a difference.
    provmobile's Avatar
    provmobile Posts: 4, Reputation: 1
    New Member
     
    #3

    Aug 2, 2014, 04:35 PM
    Thank you. If I can use direct bury it might be simpler although I would still have to use conduit through the sides of the buildings and down below ground level. It is not a direct line from where I will have to go into the buildings as I will have to ditch around the end of a sidewalk that extends from the side of the house a short distance. I forgot to include that in my question, so I remeasured and the run will be closer to 65 feet from breaker box to box.
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #4

    Aug 2, 2014, 06:22 PM
    UF-B can be run through conduit for protection. However, it is not just Ampacity, it is rated on how it is used. For example, if you are going to be running motors, you need to multiply their amperage by 125% for total amperage. Straight amperage for 6/4 UF-B is 55 Amps. However, if you are going to be running a lot of motors at the same time you may need to increase you breaker size and then upgrade to 4/4. What are you planning to be using? Voltage drop would be minimal, less than the maximum 5%. With a subpanel you will also need a separate grounding rods, 2 of them at least 6ft. apart, at the shop. Read up on installing a subpanel before buying the wire. In older days you could use a 3 Conductor.
    provmobile's Avatar
    provmobile Posts: 4, Reputation: 1
    New Member
     
    #5

    Aug 3, 2014, 08:31 PM
    I will be doing hobby auto work mainly. I will have fluorescent lights and bench grinder along with drills and hand held buffer, etc. I would like to be able to use a small welder at some time.
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #6

    Aug 4, 2014, 01:06 PM
    You should be OK with #6/4 to the breaker box.
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #7

    Aug 4, 2014, 06:46 PM
    Depending on where you are located this likely needs a permit and they would require a sub panel inside the shop.
    provmobile's Avatar
    provmobile Posts: 4, Reputation: 1
    New Member
     
    #8

    Aug 5, 2014, 09:47 AM
    Thank you for the info.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

What Kind Of Pills Are These And The Spec Please [ 24 Answers ]

I Found A Round Pill That Is White And Has A Number 512 On One Side Then A Line On The Other I Was Told It Was A O.codone Is That True I Found A Pill With A Cursive V On One Side On Other Side It Has A Line And A Number That Says 35 92 It's A Oval Shape I Was Told It Was A Vicodin

Torque spec. for 200 amp main breaker on copper wire [ 2 Answers ]

I'm using a GE 200 amp main breaker box, look inside the pannel box to see the Torque spec. is the torque setting inside for Al. and copper wire?

Need spec for blower motor [ 3 Answers ]

Hello, The bearings on my blower motor are starting to go and I need to replace it. Unfortunately, it is so old that some of the relevant information has worn away from the label. Here's what I know: Furnace: Mueller Climatrol Oil Furnace model #227-80 Components seem to have part # 498-65...

Torque spec [ 2 Answers ]

What is the torque setting for the serpentine belt tensioner on a 1997 Lumina with the 3.1 V6?

Need Spec Information on Unit [ 5 Answers ]

I have a condesor I believe.. it's a Coleman Evcon DCRS 036B is the model number I believe. Can anyone tell me anything about this unit. Tonnage size, what my guages should be reading to see if I am low, etc.. Thanks Ben


View more questions Search