Ask Experts Questions for FREE Help !
Ask
    MaxSteel's Avatar
    MaxSteel Posts: 2, Reputation: 1
    New Member
     
    #1

    Sep 3, 2007, 11:05 AM
    Switch Controlling Half of a Receptacle issue.
    Hi there, I'm having a slight issue, and I don't know what I did.

    I replaced all of my outlets with a newer style. However, one (half of an) outlet USED TO be controlled by a switch that's 5 feet away.

    Now this switch does nothing. The outlet is completely hot at all times on both outlets. How can I fix it so that half of the outlet is controlled by the switch again? :confused:

    Thanks!
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #2

    Sep 3, 2007, 12:05 PM
    Between the two brass screws there is a very small jumper that needs to be removed. You may need to use a small flat screwdriver or a needlenose pliers to pry it out.

    The hot live feed will connect to one screw, and the switched hot wire from the switch will connect to the other screw.
    MaxSteel's Avatar
    MaxSteel Posts: 2, Reputation: 1
    New Member
     
    #3

    Sep 3, 2007, 12:57 PM
    After some research, that's what I came up with too! I've tried it in the meantime, and you are absolutely correct. It was that "simple"..

    Thanks a bunch for replying so quickly!

    .\\ax


    Quote Originally Posted by tkrussell
    Between the two brass screws there is a very small jumper that needs to be removed. You may need to use a small flat screwdriver or a needlenose pliers to pry it out.

    The hot live feed will connect to one screw, and the switched hot wire from the switch will connect to the other screw.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Half bat-half man [ 3 Answers ]

I am trying to find the name of a movie from the 70's... There is a mad scientist on an island who intertwines animal dna with human dna... it's probably cheesy fx with costumed people. I saw it when I was a kid so I was amazed... I know there was a butterfly woman and at the end a half bat-half...

3 and 4 way switch wiring issue [ 1 Answers ]

I purchased a Leviton PR 180 motion activated light control, but was wondering if this could be wired to replace the current 4 way throw switch in its current location. The current 4 way switch is in a 3-switch configuration, but was placed in a location where a motion sensor would work better. ...

Combination switch and receptacle? [ 2 Answers ]

How do I install a combination switch and receptacle. I presently just have a light switch? Thank You.

Light and switch issue [ 3 Answers ]

I am attempting to replace an existing light fixture. I have discovered four wires coming into the opening. When I connect the new light *** the old one was I only have power before the light and the new light comes on. No power to the rooms beyond the light. In addition, the new light is on...

My Half Dachshund Half Chihuahua has potty problem! [ 3 Answers ]

Hello my My Half Dachshund Half Chihuahua is a great dog but when it comes to the potty he is not good. He is let outside every hour but sometimes he pees in the house. I stay with him outside for 30 minutes and let him inside. I have no solution what should I do? :confused:


View more questions Search