    Splitting overloaded circuits
    I have a few circuit breakers in my house that, between outlets, lights, ceiling fans, and vent blowers, have as many as 18 items on a single circuit. I know that's too many. Question is, how can I tell where to disconnect and run a new line to the circuit breaker box in order to split the load in half or in thirds?
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #2

    Dec 14, 2011, 07:40 PM
    You need to determine exactly what items are on the circuit and how many total watts or Amps are used. Lights are easy, watts, then watts/volts=Amps. Vent fans are most likely Amps. Then do a circuit layout of all the items and determine where to break the circuit. You will need a junction box, easily accessed, where you can tie the new line in. Some people install a double Old Work box but install only 1 outlet and blank out the other side to get the space for the connection. Make sure your new line and breaker is of the proper ampacity.
    GaryRL's Avatar
    GaryRL Posts: 2, Reputation: 1
    New Member
     
    #3

    Dec 14, 2011, 08:22 PM
    In doing the circuit layout, are there any tools to help figure out how the wiring runs from item to item? Is the outlet on that wall before or after the one in the next room. Each of the circuits go into two or three rooms.
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #4

    Dec 15, 2011, 03:08 PM
    Hard to say not knowing how your house was wired. You can buy some testers but they only tell you that power exists. I have never seen a circuit that loops back and forth from one room to another. If you feel comfortable doing this, determine the circuit layout, turn off the power and then disconnect 1 side of a duplex outlet that is about half way in the circuit. Wire nut the cold side wires and then turn on the power, you will have power to some but not others. Depending on the load, you could possibly start your new circuit there.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Am I overloaded with amps? [ 1 Answers ]

I have a 55" rear projection big screen TV, Directv Dvr box, Wii, PS3, Laptop, and a Desktop that id like to run off 1 grounded outlet with a surge protector. The only thing is, is that its all on 1 - 20amp breaker. Is that too big of a load and can anyone offer suggestions?

Is this panel overloaded? [ 1 Answers ]

I recently purchased a seasonal home 600sqft (lower NY state). The only source of power is electric. I did major renovations and expanded the curcuits in the panel. I need to understand what I have and if I need to upgrade service to the house or replace the panel. 1- The main panel has what...

Splitting up [ 4 Answers ]

Hello well its not really about dating but really need some advice , my ex and me split up about one month ago I caught him in bed with another woman , and found out since we finished he has had numerous women in the three years , I can't seem to get over this he abused me emotionally to. Any...

Is my 100 amp panel overloaded? [ 5 Answers ]

My main panel is 100 amps and was completely full with about 10 breakers. About 5 years ago I had an addition put on the house and the contractor said that the service would need to be upgraded (but didn't specify how). After the licensed electrician left ,I realized that he had installed a...

Did one leg of our 1950's 100 amp main breaker fry because it was overloaded? [ 1 Answers ]

Did one leg of our 1950's 100 amp main breaker fry because it was overloaded by too many dedicated circuits? We have a main breaker with two "legs" outside our house and our main panel inside. Last week, an electrician installed 4 new dedicated circuits -- one each for microwave, kitchen...


View more questions Search