    Replacing Sub Panel
    The hot wire to my new Sub-Panel is now to short. Can or how does one splice additional wire needed to reach mounting point? I'm short by 13 inches.

    Thank you in advance for any helpful reply... BRAD
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #2

    Dec 17, 2007, 06:13 PM
    In an accessible junction box outside the panel.
    Washington1's Avatar
    Washington1 Posts: 798, Reputation: 36
    Senior Member
     
    #3

    Dec 17, 2007, 06:59 PM
    My question would be. How long is the feed from the main to the sub? Are you using copper or alum? What size wire are you currently using?


    Keepitsimple,

    You can also splice inside the panel.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #4

    Dec 18, 2007, 02:31 PM
    Why outside the panel?

    If the feeder cable is long enough to be properly connected to the panel, and only one wire is too short, you may splice with wire to lengthen it inside the panel.

    You may use the same size wire of the same material with the same type of insulation and connect both with a split bolt connector, that will need at least two layers of electrical tape, or there are mechanical lugs already pre-insulated.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Replacing fuse box with Circuit breaker panel [ 3 Answers ]

I want to replace an old fuse box with a circuit breaker panel. Do I need a 200 AMP service? (considering putting in air conditioning in the future). The house has two apartments so I want to make sure there is adequate service. As I know absolutely nothing about this, what questions should I...

Breaker size in main panel to support sub panel? [ 7 Answers ]

Hello, I am wiring a sub-panel to the outside of my home (50 feet from main 200 amp box). I ran 3 wire - 6 gauge. What is the largest 2 pole breaker I can put in the main panel to supply the sub-panel. TYPE NM-B 6-3 WITH GROUND 600 VOLTS CIRTEX-I EZ-STRIP (R) PLUS 17:11 2/5/07 SB/RC ...

200 AMP Service panel to 200Amp Sub Panel [ 1 Answers ]

I getting new 200Amp service to surface mount service panel. I want to run 2oo cable to bring it sub panel in my Garage which is approx 120Ft Run through ceiling. 2 Questions 1. Is there any ristriction on running a 200AMP inside house to garage ? 2. I got a dirt cheap subpanel that has...

Main Circuit Panel to Branch Panel? [ 1 Answers ]

Hello experts, OK... My Main Load center in my home has a branch circuit connected to a 60 amp breaker. The branch feed wire is a 4awg copper wire. The branch panel is downstairs and it has a 100amp main cutoff breaker installed in it. It feeds the whole downstairs including... (1)...

Kenmore Elite Dryer Toe panel - how to get panel OFF! [ 3 Answers ]

I have a Kenmore Elite Model # 110.600094990 27 inch Electric Dryer - NOW How the heck does one take the Toe Panel Off / or Open this lower section of the dryer? There are two lower edge clips and two upper edge retainers. I CAN NOT get the panel to budge! This is a 7 yr old unit. Thx DAS


View more questions Search