    Panel Replacement
    I have a ge panel and one of the breakers won't reset. Got an estimate and electrician said the faulty breaker is a Siemens tandom (double) breaker in 1 slot. He said you can't have Siemens breakers with a ge panel. Is this true? Also that ge doesn't make tandom breakers. I researched and found that they do make slim line breakers. Shouldn't he of mentioned this? We don't have any extra slots on our panel and he wants to replace our panel. Says it won't pass if inspected. We have been in our house 10 years and had basement finished 6 years ago and panel was added to.


    HELP!
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    Mar 2, 2015, 01:57 PM
    You would need to contact GE to see if a Siemens is cross referenced for their panel. If it is not you would likely not pass an inspection and this could void your insurance if there were to be a fire
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #3

    Mar 2, 2015, 02:44 PM
    Remove the wire from the breaker and see if it will reset.

    Also see this web site on the subject;
    http://forums.mikeholt.com/showthread.php?t=142390
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #4

    Mar 2, 2015, 06:32 PM
    GE does not make tandem breakers, they make slim as you found out, acceptable to use them. Sometimes they don't fit every panel. look at the slot where it connects to the buss. Check at HD in the breaker area. They usually have a cross reference sheet that shows compatibility, my store does. He is correct that you can fail a Homeowners Insurance or other inspection with mismatched breakers. I work with RE agents doing inspection checklist repairs with sales of homes and that is a commonly noted area.
    donf's Avatar
    donf Posts: 5,679, Reputation: 582
    Printers & Electronics Expert
     
    #5

    Mar 3, 2015, 07:27 AM
    Just to chime in here, exactly what is the failing breaker used for?

    Also, the panelboard's label will tell you the type of the breaker's to be used. If the breaker conforms to the specifications of the approved breakers for that panelboard you should be fine. However, that said, I only use exact factory replacement breakers for the panelboard in question.

    Also, why are you considering the panelboard, as your title bar indicates, for a suspect breaker? Is there more going on here than you have told us?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Breaker Panel Replacement [ 4 Answers ]

Will I have any problems with a building inspector if I pull a permit to replace the pushmatic breaker panel but leave all the clothe wrapped wire (Assuming the cloth wrapped wire was to code when it was installed)

Replacement etched glass panel [ 1 Answers ]

Looking for an etched glass panel for a dining room chandelier. Has a hope in it for hanging from a wire peg on chandelier. I believe the light has 6 or 8 panels plus a center drop down spot light. Bought from Home depot 6-8 years ago. Could be a Hampton Bay light.

DIY panel replacement Q's [ 2 Answers ]

I live in unincorporated Harris County, TX (outside houston city limits). We just bought a house built in 2001 but there appears to be some existing water damage (corrosion) on all the breakers in the panel - likely from Hurricane Ike. Recently (last week) a lizard somehow got behind the...

Fireplace panel replacement [ 1 Answers ]

I have a True Heat Model TH42 Fireplace. The company is no longer in business. I need the replacement panels for the sides and back. The floor also has a crack running from the front to the back. Can I get replacement panels for this and where? Can I put the fireplace caulk on the floor or should I...

Challenger SB20 Disconnect Panel Replacement? [ 1 Answers ]

Hello all... I am new on this message board. I have a hopefully simple question. I need to replace the buss bar unit in my Challenger SB20 (200 amp) home disconnect panel. I have searched for individual parts, complete panels and have found nothing. Is this company STILL in business? Does anyone...


View more questions Search