    Main Circuit Panel to Branch Panel?
    Hello experts,
    OK... My Main Load center in my home has a branch circuit connected to a 60 amp breaker.
    The branch feed wire is a 4awg copper wire. The branch panel is downstairs and it has a 100amp main cutoff breaker installed in it. It feeds the whole downstairs including...

    (1) 40amp - Hot Water Heater
    (1) 20amp - Washer
    (1) 30amp - Dryer
    (2) 20amp - 10 plugs(goes from breaker to 2 junction boxes in ceiling then split to each plug)
    (1) 20amp - 4- 4ft fluorescent light boxes
    (1) 30amp - Branch circuit to pool house via an underground pvc pipe.


    My question is really 3 fold...

    1) Should I run a new 2awg wire from main panel to branch circuit panel in order to get 100amps downstairs and install a 100amp branch circuit breaker in main panel to feed it?

    2) Should the main breaker in the main panel have the same size breaker as the main breaker in the branch circuit?

    3) Am I overloaded downstairs?
    :confused:
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #2

    Apr 2, 2007, 03:29 PM
    Even thou #4 is allowed for 100 amp residential, would be good to get more copper, or even #2 aluminum will be a adequate for a full 100 amp capacity.

    You have three large appliances that will likely run together, so load will be about 65 amps running hard and steady. So I think your pushing it, and can be a good thing to get some cushion.

    If your CB at the end of the feeder is 60 amp is fine, one more layer of protection.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Difference between Main Lug and Main Breaker Panel [ 8 Answers ]

What is the difference between a Main Breaker Panel and a Main Lug Panel and can either be used in new residential construction.

Main Electrical Panel [ 1 Answers ]

We want to add a deck off our master bedroom. The main electrical box/outside will have to be away from the house it will be in the way. There is no where to move it on the back of our house, too many windows and doors. Were can we move it? How far? Can we attach to a pole, garage, or a shed? We...

Main panel as subpanel [ 2 Answers ]

Hello: I stumbled across your forum and found a question that was close to mine, but have a more detailed query. I am wiring a shop/apartment. The building has a 200 amp service panel. The main loads (a/c, range) and dedicated loads (fridge, smoke detectors, etc) are branch circuits on the main...

Main Service Panel needs [ 9 Answers ]

I ran across this site accidentally today and found someone who had many of the same issues I need help with. Most of my questions were answered reading the forum however I have one more, using the following information I am hoping someone can help. The existing house is apx. 2300 sq ft w/a 200...

Sub Panel with a main in Position 2,4, 6 [ 2 Answers ]

My question concerns panel boards where the main breaker takes up two or three positions on the panel board. If I use a main in position 2,4,6 the corresponding positions 1,3,5 have to be left blank according to code.


View more questions Search