    Junction box proximity to water lines
    I've recently begun finishing my basement. In the mechanical room, I have a series of junction boxes about 2' away from my manablock system and will likely have a sewage ejector pump running overhead in the future...

    I'm not a fan of junction boxes and, of course, never hide them; but I was left little choice on this project. The electrician left me a couple of stubs of wire for the circuits in the basement with a couple others run very poorly and without enough slack to run them straight to the fixture.

    I may be able to move the junction boxes and re-run a couple of circuits to get more space, but ~4' is all I'll be able to manage. I have a bit of an uneasy feeling about the location, but am I violating any code?
    Attached Images
     
    stanfortyman's Avatar
    stanfortyman Posts: 5,598, Reputation: 279
    Electrical & Lighting Expert
     
    #2

    Jun 8, 2010, 06:23 PM

    There is no problem, safety issue or code issue with your set up. In fact, as long as they are not touching they can be as close as you can get.

    I am personally not sure what this common phobia is with boxes and water lines.

    I am NOT suggesting this (obviously), but you could spray those boxes down with a hose and nothing will happen. Other than maybe a GFI tripping.
    Missouri Bound's Avatar
    Missouri Bound Posts: 1,532, Reputation: 94
    Ultra Member
     
    #3

    Jun 9, 2010, 07:42 PM
    From what I can see, your electrician did a pretty neat job. (IMO) And the labeling is a bonus.
    IDOC21's Avatar
    IDOC21 Posts: 9, Reputation: 1
    New Member
     
    #4

    Jun 10, 2010, 05:22 PM

    I was actually the electrician on this job... I was referencing the original electrician... not a criticism though... I didn't pay for a finished basement.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Junction box [ 2 Answers ]

I know a electrical junction box must be accessible, but can it be covered by a medicine cabinet that can be removed? The cabinet will be surface mounted.

Junction box [ 1 Answers ]

Is there a limit to how many feeds can come out of a junction box. I have a 4" metal box in my attact for my bathroom, Id like to run one feed for the receptical, one for the vanity light and one for recesed lights / fan. I s this OK?

Junction box under panel box? [ 1 Answers ]

I am bringing new underground cable into an unfinished garage which is coming directly from the meterbase. The cable will come out of the ground at the garage, run up the outside of the wall for approximately 3 feet (obove the 2 high cinderblocks) and then go through the wall where it will connect...

Junction Box [ 1 Answers ]

Is it OK for metal junction boxes to come in contact with insulation?

Another Junction Box ? [ 9 Answers ]

Again, thanks to everyone for all their valuable information as I wire up my Recording Studio addition. :) You guys are great! ;) I have another question reference the use of Junction boxes. On a couple of my framed walls, where I wired in outlets, some of the outlets (for like Exit Signs) are...


View more questions Search