Ask Experts Questions for FREE Help !
Ask
    jolon's Avatar
    jolon Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 21, 2012, 04:41 AM
    Junction box
    I removed my old medicine cabanet that had two lights attached to it from my bathroom wall. I found two 14/2 wires coming into the junction box that these lights were wired to. I am installing a new light fixture only to replace these old one. Which one of these two 14/2 wires do I connect my new light fixture to?
    stanfortyman's Avatar
    stanfortyman Posts: 5,598, Reputation: 279
    Electrical & Lighting Expert
     
    #2

    Oct 21, 2012, 02:52 PM
    Just connect the new one exactly the same way as the old one was wired.
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #3

    Oct 21, 2012, 03:09 PM
    I will assume you have a connected wire set from one light to the other. Disconnect both sets and find the matched pair. With the switch off, temporarily connect the new light to one pair and turn on the switch. If it lights that is the pair. If not, it's the other pair. Or use a VOM to check the voltage.
    donf's Avatar
    donf Posts: 5,679, Reputation: 582
    Printers & Electronics Expert
     
    #4

    Oct 21, 2012, 05:45 PM
    I believe you are looking at a "Supply Line cable" and a "Switch Loop cable."

    Of course that is guessing that you have a light switch controlling these lights,

    If this is true, you must first determine which cable goes to the switch and which cable is bringing the supply voltage to the junction box.

    Once you know which cable has the black & white from the feed, you connect the black from the feed to the white to the switch. NOTE: please mark the white wire to the switch with either a black sharpie or wrap it with black electrical tape at both the junction box end and the switch end.

    Next, connect the black return wire from the switch to the black lead for the light. Finally, connect the white from the supply cable to the white from the light. Also connect all bare or green wires together and to the junction box if it is a metal box.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Junction box [ 2 Answers ]

I know a electrical junction box must be accessible, but can it be covered by a medicine cabinet that can be removed? The cabinet will be surface mounted.

Junction box [ 1 Answers ]

Is there a limit to how many feeds can come out of a junction box. I have a 4" metal box in my attact for my bathroom, Id like to run one feed for the receptical, one for the vanity light and one for recesed lights / fan. I s this OK?

Junction Box [ 1 Answers ]

Is it OK for metal junction boxes to come in contact with insulation?

Another Junction Box ? [ 9 Answers ]

Again, thanks to everyone for all their valuable information as I wire up my Recording Studio addition. :) You guys are great! ;) I have another question reference the use of Junction boxes. On a couple of my framed walls, where I wired in outlets, some of the outlets (for like Exit Signs) are...

15A off a 20A junction [ 2 Answers ]

Is it OK to take a single 15A line off a 20A branch circuit. Specifically, I have a new 20A kitchen wall circuit which will exist only of two 20A counter GFCI outlets. I have had to rework that wall for the gas stove and want to run a 15A outlet for the gas stove electrics. Can I just take a 15A...