    How to wire a 70 amp box with one 20 amp in and to 20 amp out?
    I am running a 12 gauge 20 amp wire from a main box to a separate 70 amp box with 2-20 amp breakers to feed 2 separate circuits. With the one line coming in do I piggy tail the 2 brekers to the one 12 gauge wire coming in?
    Missouri Bound's Avatar
    Missouri Bound Posts: 1,532, Reputation: 94
    Ultra Member
     
    #2

    Dec 13, 2010, 06:49 PM

    Not sure what you mean, but most assuredly as you say it it's a NO. One breaker, one circuit. If can you explain in better detail I may be able to clarify my answer.
    deerhunter1234's Avatar
    deerhunter1234 Posts: 2, Reputation: 1
    New Member
     
    #3

    Dec 14, 2010, 07:09 AM
    Comment on Missouri Bound's post
    Thank you for your answer. I thought I could do it but found out I can not. I have one 12-2 wire coming into the 70 amp box. I wanted to run 2 separate 20 amp circuits but now I know I can only run 1. I should have ran a 4 wire into box than I could
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #4

    Dec 14, 2010, 07:31 AM

    Why a subpanel for two 20 amp circuits, and the feeder is 20 amp?

    I do not see a need for a 2 circuit subpanel, as you stated, run a 4 wire #12 with two 20 amp circuits and eliminate the subpanel.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Electrical Code - Can you drop a 75 amp power source into a 175 amp box? [ 0 Answers ]

I am not an electrician, but work in Safety. Someone in maintenance was asked to drop a power cable from a 75amp bus box to 1 175 amp electrical panel for a large machine that is being installed. They wanted to troubleshoot part of the panel and there was currently no power connected, so they...

Can a 150 amp meter panal handel a 100 amp, 40 amp, 30 amp and 30 amp brakers. [ 2 Answers ]

My meter panal is a 150amp panal. I have a 60 amp sub panal coming off it a 30amp to my stove a 30 to dryer and a 40 to the a/c. i want to upgrade the 60 amp sub panal to a 100 amp panal. Will the 150 amp meter panal handel it or do i need to have a 200 amp meter panal installed

How do I wire a hundred amp box to replace two old 50 amp ones [ 1 Answers ]

I was told that I could possibly do the work myself or get a friend to help do it that is not licensed to do it. He told me he thought there was a way to do this since it is a home owner issue for me. My dad owns the deed on my place and is OK with me having the work done if it is legal to do...

Identify 100 Amp vs 200 Amp Household Breaker Box [ 10 Answers ]

In my home Breaker Panel there are two breakers connected by a bar (labeled "Service Disconnect"), each breaker has a "100" written on them. Is this a 100 amp or 200amp Breaker box? Salesman wants to know what size Breaker Box I have in order to order to correct tankless water heater.

400 amp service with 2-200 amp panels & 320 amp socket [ 6 Answers ]

Hi TK. I am running 400 amp service into my new contruction home. The electric compnay is running a single 400 amp line to the meter. I have to split it to the two panels at that point. You had told me once before that I need a 320 amp meter socket and then run 2-200 amp lines to the separate...


View more questions Search