How do you wire a 3 way switch - black screw connected to white wire is this right?
I have a 3 way switch I am replacing. It has 4 wires coming out of the outlet.
The top two terminals I am going to wire Red left and Black right. The bottom two terminals will be ground left and white right on the black screw terminal. This does not seem right, but an electrician said it is correct. The switch is supposed to operate an outside light. The switch is just inside the house. Is the wiring scheme correct?
|
|
|
Electrical & Lighting Expert
|
|
Jul 27, 2010, 05:44 PM
|
|
What you are asking is impossible to answer without more information.
There is no set-in-stone color scheme for 3-way switches. The only thing that is set in stone is that the ground must go on the green screw.
Also, left and right are meaningless. There is no left and right on a 3-way switch. The black screw is called the "common", not for any particular reason though. The two gold screws are the travelers. The same two wires used as the travelers must go on the gold screws on both switches.
How was the old switch wired?
|
|
|
New Member
|
|
Jul 27, 2010, 05:57 PM
|
|
Thanks for your response. The old switch had the black wire on the bottom and the red and white on the top. No ground was used. My electrician friend said something about this is a California 3 way suicide kill switch scheme and the white wire should be on the bottom (black screw) opposite the green ground wire. The other two (red and black on the top). Hope that makes sense.
My thinking was that the black wire needed to be on the bottom (black screw opposite the green screw ground wire and the red and black wire on the top.
|
|
|
New Member
|
|
Jul 27, 2010, 05:57 PM
|
|
Thanks for your response. The old switch had the black wire on the bottom and the red and white on the top. No ground was used. My electrician friend said something about this is a California 3 way suicide kill switch scheme and the white wire should be on the bottom (black screw) opposite the green ground wire. The other two (red and black on the top). Hope that makes sense.
My thinking was that the black wire needed to be on the bottom (black screw opposite the green screw ground wire and the red and black wire on the top.
|
|
|
Electrical & Lighting Expert
|
|
Jul 27, 2010, 06:11 PM
|
|
Again, left right, top bottom. All meaningless. Different brands have different screw positions.
You need to find what wire was originally on the black screw and copy that. The other two should not matter then.
If it actually IS a "California 3-way" then re-wire the whole thing properly.
|
|
|
New Member
|
|
Jul 27, 2010, 06:23 PM
|
|
Like I said, when I pulled off the old switch, The black wire was on the bottom of the switch and the other 2 wires, Red and white at the other end. No ground. Now in my book, if I rewire it exactly the way it was, I place the black wire on the black screw. The other two wires (red and white at the other end of the switch. I just want to be sure... Calif. 3-way "Re-wire the whole thing properly" tells me what? Thanks...
|
|
|
New Member
|
|
Jul 27, 2010, 07:08 PM
|
|
This may help you.
|
|
|
New Member
|
|
Jul 27, 2010, 07:10 PM
|
|
|
|
|
Electrical & Lighting Expert
|
|
Jul 27, 2010, 08:11 PM
|
|
Originally Posted by buzzyspeedo
Like I said, when I pulled off the old switch, The black wire was on the bottom of the switch and the other 2 wires, Red and white at the other end. No ground. Now in my book, if I rewire it exactly the way it was, I place the black wire on the black screw. The other two wires (red and white at the other end of the switch. I just want to be sure..... Calif. 3-way "Re-wire the whole thing properly" tells me what? Thanks...
Not much I guess.
Sorry, I really have no way to figure this out for you.
|
|
|
New Member
|
|
Jul 27, 2010, 08:14 PM
|
|
Good diagram Thank you !
|
|
|
New Member
|
|
Jul 27, 2010, 08:40 PM
|
|
|
|
|
New Member
|
|
Jul 27, 2010, 08:42 PM
|
|
|
|
|
Uber Member
|
|
Jul 28, 2010, 06:45 AM
|
|
If it works, leave it alone, Wrap tape around the white wire, Like stan Keeps saying, "The wire on the darkk screw is what is important, Not left,right, top or bottom".
The Electrician says its fine, so I am thinking it is working?
Black tape on the white wire.
|
|
|
Printers & Electronics Expert
|
|
Jul 28, 2010, 07:27 AM
|
|
The reason you wrap the black tape around the white wire is because of the NEC code.
Since most switches do not use a neutral conductor. The NEC allows the Neutral conductor to be "re-tasked" as an ungrounded conductor.
This means that the NEC allows the White conductor to carry voltage from the power source to the switch only.
The white wire can only supply a switch and it must be marked at both ends to signify that is re-tasked.
|
|
|
New Member
|
|
Jul 28, 2010, 08:49 AM
|
|
Okay, Here is what I think I am hearing." Wrap tape around the white wire, Like stan Keeps saying,"
Does that mean it is OK to place the White wire on the dark screw (c), but mark it by placing black tape on it? Or does it mean to NOT use the White wire, but to tape it off and instead use the Black wire? I am obviously a novice and do not know these terms nor do I want to assume anything this serious. Thank you all for your patience. Much appreciated.
|
|
|
New Member
|
|
Jul 28, 2010, 08:53 AM
|
|
Honestly, I think this could be figured out if I knew where the other switch was that connects to the switch in question. Right?
I could see how it is wired and then know which was the traveler.
Since the switch in question is not working, I honestly do not know where the connecting switch is? Make sense?
|
|
|
Printers & Electronics Expert
|
|
Jul 28, 2010, 09:08 AM
|
|
There are two possible conditions for using the three-way switch.
One: (most common) is control lights from two locations.
Second: Have one switch control two devices.
For example: One switch with two sets of lights.
Which is the environment that you have?
When you put the switch on, what is supposed to happen?
|
|
|
Uber Member
|
|
Jul 28, 2010, 09:09 AM
|
|
This question is IMPORTANT.
Does the light currently work?
If you can't find the second switch of this 3 way, it may have been eliminated at the location with 2 wire tied together and the other traveller capped off.
We are saying to wrap black tape around the white wire, and leave it where it is.
From what I understand to be a California 3 way setup, and is wrong to use is have a hot on 1 traveller terminal and a neutral at the other traveller terminal on both switches, then the common of 1 goes to the lights hot, and the other common on other switch goes to the lights neutral. Problem is that sometimes the shell is hot.
|
|
|
New Member
|
|
Jul 28, 2010, 11:32 AM
|
|
Here is the short answer. The switch is supposed to turn on the light just outside the house only. I am not sure what else it may operate.
The reason I replaced the switch in the first place is because the switch template was metal and would short out at times. This would blow the breaker and the TV and stereo would shut off as well, I saw black marks on this metal template which made be conclude that it was shorting. SOOO I got rid of the metal faceplate and then as secondary cautionary step I elected to replace the existing switch with a new one. Now that the new switch is slightly different than the old switch, I want to be very sure that I put the wires on correctly. The old switch had the black wire at one end (that had only 1 input and the other end had the red and white wires. There was no input for a ground wire. The ground wire was not connected. Does this help?
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Black wire red wire and white wire spliced to 10/3 on a 220 circuit
[ 25 Answers ]
I have installed a disconnect between my dryer receptable and a tanning bed. I want to splice the 10/3 box wire to the existing 220 wiring at the dryer.
Dryer= red, black, white and bare ground wires
10/3 wire= black, white, and bare ground
How do I splice these to allow the disconnect box to...
Why was the Blue wire connected to a blank screw?
[ 5 Answers ]
Hi. I just replaced my old mercury thermostat with a Honeywell RTH2310. The old wires were : yellow connected to a "Y" screw, Green connected to a "G" screw, White connected to a "W" screw, red wire connected to "Rh" screw and a Blue wire was connected to a blank screw, but was right next to an...
View more questions
Search
|