    Oct 24, 2008, 10:49 AM
    GFI wireing
    I am planning on wireing basement shop outlets. Do I need to use GFI outlets? Can I use one GFI outlet in a run with non GFI outlets? How many outlets can have in a circuit? Should I use 12/2 wire with a 20 amp circuit breaker?
    WallyHelps's Avatar
    WallyHelps Posts: 1,018, Reputation: 136
    Ultra Member
     
    #2

    Oct 24, 2008, 12:13 PM

    Yes, I would use 12/2 wire and a 20 amp breaker. There probably is a code limit on outlets/circuit, but the important thing is how many amps are you pulling. I'd say a reasonable limit for a 20A circuit would be 4 or 5 (duplex) outlets.

    As far as GFI's go, if there is no chance you could be standing in water while using your power tools, I'd skip them. My experience is that some shop equipment will trip them unexpectedly.

    Hopefully, some of the other experts will chime in regarding if this is a National Electric Code issue or not.

    Good Luck,
    WallyH
    stanfortyman's Avatar
    stanfortyman Posts: 5,598, Reputation: 279
    Electrical & Lighting Expert
     
    #3

    Oct 24, 2008, 12:52 PM
    Quote Originally Posted by WallyHelps View Post

    As far as GFI's go, if there is no chance you could be standing in water while using your power tools, I'd skip them. My experience is that some shop equipment will trip them unexpectedly.
    If this is an unfinished area of the basement, and a shop surely is, then GFIs are mandatory. Today's GFI's are mush more resistant to nuisance tripping.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Thermostat wireing [ 11 Answers ]

I Need help installing a rth6300b thermostat I have 8 wires comeing out of the wall they are orange,brown,black,white,green,blue,yellow,and red own the back of the of the thermostat there is g , w , y , r , and rc can someone please help?:confused:

Shop wireing [ 3 Answers ]

I am rebuilding a shop that is 150ft from my meter. I want to have a lug meter installed so I can have a 200 amp service to my shop. 30x40 with a 15x40 lean too. Do I need 2/0 cable to run this length? Also is there any way that Ican legally pull a permit and do the work myself? I have heard diff....

Electrical wireing [ 3 Answers ]

Do I have a broken nuetral wire if the 1st 3 outlets are good on a circuit? Then from that point what to copper or black to copper lites tester black with white nothing.

220 wireing [ 2 Answers ]

How many wires does 220 central air have going to the copressor unit outside


View more questions Search