    Hi, I am running 8-3 underground in pvc conduit and am wondering:
    1. How high up the garage wall I should come up before entering the garage (I guess this means how high the panel will be on the inside as well)? Any code for this or is whatever height is comfortable good enough?

    2. Also, I am running 40 amps 220 volts out there, but the panel I bought is Cutler Hammer 100amp value pack just because I wanted a circuit breaker out there and 100 was the lowest they had. Is this overkill? Should I go with just a main lug? Please help. THanks in advance!
    Regards,
    Steve
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #2

    Jun 27, 2006, 02:30 AM
    The UF cable can enter anywhere is comfortable, if open to damage, then protect it inside a wall or sleeve with conduit. The top of the panel should be no higher than 6.5 feet.

    The 100 amp panel is fine, just cannot use the 100 amp breaker, MLO would be better, and rely on the 40 amp breaker back at you main panel to protect this circuit and panel .
    stevanrk's Avatar
    stevanrk Posts: 38, Reputation: 1
    Junior Member
     
    #3

    Jun 27, 2006, 06:44 AM
    Thanks a lot tkrussel! That's a cheaper solution than the panel I bought!

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Sub panel for garage/addition [ 24 Answers ]

Hey guys I am working on an addition to my home and was hoping to get some advice on the sub panel I plan on installing in the new garage. The existing house is 200 amp service and about 3500sq/ft. I will be adding an additional 1800 and will include the following: 2 half baths 2 full baths 2...

Detached garage pad [ 2 Answers ]

I am trying to get some information on building a garage starting with the Pad. I am planning on building a 22X26 detached garage. The rough grade was completed about 4 months ago. It is a clay base with no topsoil added yet. Should I get a bobcat in to remove a couple inches or just pack down...

Detached garage grounding rod or not [ 1 Answers ]

Hi, I just ran across another problem. I will be running 40 amps 240 volts out to my garage via underground 8-3 plus ground. Do I need a grounding rod at the garage or is the ground via the service cable to the garage enough? I have seen both and am not sure why. Is the 240 volt service to the...

Washer hook ups in detached garage [ 5 Answers ]

I would like to move my washer and electric dryer from their present location off the kitchen, to the back inside wall of my detached garage. It is approx. 35' from the back of the house, to the location in the garage. My house has no basement, but has a crawl space underneath. I 've checked...