Ask Experts Questions for FREE Help !
Ask
    Kiwii's Avatar
    Kiwii Posts: 1, Reputation: 1
    New Member
     
    #1

    Nov 17, 2010, 10:53 AM
    Converting from 200 Amp to 400 Amp service-Need some advice
    Currently have 200 amp meter, 200 amp breaker disconnect (main service panel), and a 200 amp subpanel in a Manufactured home. I want to upgrate to 400 amp meter to service the home and a new shop with 200 amp. I have talked with the utility and local electrician and electrican engineers, but I want to be sure I have this right.

    Meter: Cooper B-Line 342C, with extra lugs to service 2-200amp disconnects. Wire 4/0-4/0-2/0 from new meter to new 200 amp disconnect (square D Q22200NRB 200 amp circuit breaker and box with bondable neutral and equipment grounding lugs). Also tie bare copper ground from new 200 amp disconnet to the grounding rods already installed for the existing 200 amp service. Run the 4 wire in 3 inch conduit to the new shop, and wire 2 hots, 1 neutral, and 1 ground (4/0-4/0-2/0-#2 all aluminum) at the shop sub panel. Do not bond neutral and ground at the subpanel.
    My question pertains to how to wire the new 200 amp disconnect with all 4 wires? Any help would be appreciated.

Check out some similar questions!

Running 100 amp service panal 200 ft away from main 200 amp service [ 4 Answers ]

I am looking to find out how big the wire needs to be to carry the load. This will be a 100 amp service coming from a 200 amp main . It will need to travel 200 to 250 ft underground to a barn. If some one could help me that would be great thaxs)))

400 amp service into (2) 200 amp panels [ 0 Answers ]

I have a job I'm looking at which has an existing 400 amp service which splits at the meter to (2) 200 amp fused disconnects and then feeds (2) 200 amp panels independently that are ion the second floor in the middle of the building. They want a 80kw generator to do the whole service with a 400 amp...

Relocating and upgrading my 200 amp service to 400 amp service [ 4 Answers ]

Im getting ready to upgrade and relocate my 200 amp service to a 400 amp service about 10 feet away away from original location. A new 400 amp meter base will be back to back with 2 new 200 amp panels. My question is, can I take out the guts out of my 200 amp panel and use it as a junction box to...

400 amp service, 2 200 amp panels, 320 amp meter socket [ 10 Answers ]

Hi, this is my first post here, but I have been reading a lot and have already learned a bunch. I want to thank TK already and hope you reply to this. I am in the process of designing my electrical system for my new home. I have some electrical experience, but am by no means a pro. I am...

400 amp service with 2-200 amp panels & 320 amp socket [ 6 Answers ]

Hi TK. I am running 400 amp service into my new contruction home. The electric compnay is running a single 400 amp line to the meter. I have to split it to the two panels at that point. You had told me once before that I need a 320 amp meter socket and then run 2-200 amp lines to the separate...