    jstenvme1980's Avatar
    jstenvme1980 Posts: 7, Reputation: 1
    New Member
     
    #1

    Jul 16, 2007, 05:59 PM
    Changing From 3 phase to 1 phase
    I have a Champion compressor I came across dirt cheap but it is 3 phase I bought a new 1 phase motor for it wired up a 220 plug and Now I need help wiring the compressor for that switch from 3 phase to 1 phase any ideas?? I am worried about smoking my new $400 motor

    Thanks in Advance
    Nick (The Mechanic Not electrician)
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #2

    Jul 16, 2007, 08:49 PM
    When you disconnect the wiring from the old motor you will see three wires (line voltage) and maybe a ground wire (usually green) remove one line wire or tape it off . The new motor may pull more amps then the old motor (compare FLA rating on both motors ) You may have to increase the wire size. Connect the two wires and ground wire to new motor following the wiring diagram on the new motor, check rotation and reverse if necessary, there is normally an arrow on the compressor pulley wheel.
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #3

    Jul 16, 2007, 09:04 PM
    Are you talking about power to the motor, or the controls? When it reaches the set pressure does it unload the valves or shut the motor down? If it had a 3 pole relay, you can just connect 2 of the 3 poles on both the line and load side. Just make sure one of them is the pole the line to the pressure switch comes off.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #4

    Jul 17, 2007, 02:42 AM
    If the compressor unit came with a magnetic motor starter, (relay), each of the 3 poles on the starter have an overload heater in line , usually at the bottom, or the load of the starter. These will need to be replaced with OLH that will match the running load amps, RLA or FAL, of the new motor. The rating of overload heaters should be 125% of the RLA.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Difference between single phase and 3-phase motors [ 4 Answers ]

Difference between single phase and 3-phase motors

2-phase vs 3-phase degrees of separation [ 5 Answers ]

At work we have 3-phase power. I understand the oscillations are 120 degrees apart. At home I have 2-phase power. Are the oscillations 180 degrees apart? I understand the neutral on a 240v circuit should carry 0 as the phases cancel each other out. My real question is that if we have a...

3 Phase vs. Single Phase [ 8 Answers ]

I am struggling with the difference between 3-phase and single phase and the advantages/disadvantages to both. Could someone help me with this, or point me in the right direction. Any help would be greatly appreciated. Thank You.

How am I going to size my 3 phase X'mer with 1 phase load using current as reference [ 3 Answers ]

Hi, I'm Peping: I have 90 pieces of single phase loads with current of 2 Amperes. This will be loaded to a 3 phase transformer, Wye connected having a line to line voltage of 220 Volts. What will be the size of the transformer required for the mentioned loads? Many thanks, Peping

3 phase vs single phase [ 3 Answers ]

Which will use less electricity: a commercial 5 ton 3 phase 13 SEER unit or a 5 ton single phase residential 20+ SEER unit? I am trying to figure out what type unit to put in our restaurant bar.


View more questions Search