New Member
|
|
Jun 28, 2010, 03:59 PM
|
|
Ceiling fans diagrams
I have a celing fan light combo. The light works from a wall switch and at the fan with a pull chain. The fan only works from a pull chain. The other day both were working, (but the light was off) I pull the chain to turn the fan off. When I went to turn the fan back on it would not work. Also the light would not come from either at the wall switch or at the pull chain. I check fuse box nothing tripped. All other lights and receptables in the room work. I am stumped.
|
|
 |
Home Repair & Remodeling Expert
|
|
Jun 28, 2010, 04:08 PM
|
|
Is there a single wall switch, controls both light and fan at the same time or are there two switches?
|
|
 |
Uber Member
|
|
Jun 28, 2010, 04:41 PM
|
|
As a wild guess, I am going to say the neutral may have disconnected in canopy, since the fan is controlled by pull chain(constant hot), light from wall switch does not control light, and other items are working. Verify bulb is still good.
|
|
 |
Uber Member
|
|
Jun 28, 2010, 08:06 PM
|
|
If both the fan and light stopped working, you should check:
1. The neutral wire in the ceiling
2. The neutral wire in the switch cap
3. The hot supply prior to the switch
A voltmeter would help.
http://www.ceiling-fans-n-more.com/c...ng-and-FAQ.php
|
|
 |
New Member
|
|
Jun 29, 2010, 10:04 AM
|
|
 Originally Posted by ballengerb1
Is there a single wall switch, controls both light and fan at the same time or are there two switches?
One wall switch that controls only the light.
|
|
 |
Home Repair & Remodeling Expert
|
|
Jun 29, 2010, 10:30 AM
|
|
This is unusual, one switch that controls light only. So does this mean the fan gets power 24/7 and can only be controlled by the pull chain or is the switch actually powering both fan and light.
|
|
 |
New Member
|
|
Jun 29, 2010, 10:37 AM
|
|
Yes the fan has power 24/7 and is contolled by the pull chain.
|
|
 |
Home Repair & Remodeling Expert
|
|
Jun 29, 2010, 10:39 AM
|
|
Have you opened the canopy and checked for lost connections yet? With the switch on your shoulde be getting 120 vac from 2 wires, both could be black but one may be blue.
|
|
 |
New Member
|
|
Jun 29, 2010, 10:59 AM
|
|
 Originally Posted by ceilingfanrepair
Thanks I will start with the light since is control by a wall switch and should be the easiest
|
|
 |
Uber Member
|
|
Jun 29, 2010, 03:53 PM
|
|
Do you have a meter?
|
|
 |
New Member
|
|
Jun 30, 2010, 08:50 AM
|
|
 Originally Posted by ceilingfanrepair
Do you have a meter?
Yes and I checked the light at wall switch and there is no power. My next move is to go into the canopy of the light and see if a wire has loosen. Need to get a tall ladder as I have those high ceilings.
|
|
 |
Uber Member
|
|
Jun 30, 2010, 02:37 PM
|
|
How did you check it at the wall switch?
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Ceiling Fans
[ 5 Answers ]
Installing a Hampton Bay ceiling fan, which is operated by a remote control unit. Wiring appears to be correct. The remote control unit works well when the receiver is loose (i.e. before finishing cover plate is applied), but when the receiver is intstalled in the mounting (according to...
Ceiling fans
[ 4 Answers ]
Bought 3 Hampton Bay ceiling fans all with remotes. Each used in a separate room. The fan in one room will turn the fan in another room off or on when it is not suppose to. There are 5 little keys in the remotes that I believe can control the fan but we did not keep the books to see how to change...
Ceiling fans
[ 1 Answers ]
OK so they are not rocket science. Now I have to install one on about a 25 degree ceiling in a cabin in the mountians. Only place is on a 6x8 beam. The wiring will have to run in conduit exposed up the beam and make it over to a vertical wall for the electrical. Can't drill into the beam and...
View more questions
Search
|