    Breaker Box Question
    I guess it would be better to call it a fuse box... not breaker.

    I live in a rather old house with k&t wiring. Our box, located in the basement, has all the wiring come in from the top. At the top of the front panel there are two black pull-out things that have markings saying main and off. They are side by side, each one with two fuses below. It seemed to me that just pulling one would kill the power to the two fuses below it, however, as far as I could tell, it killed all power. Does this sound correct?

    Also, our landlord said that a house with our type of wiring (knob and tube) does not need to have GFI on our outlets, but I think he is being a bum. Any ansight?
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #2

    Jun 16, 2006, 02:48 AM
    The pull out on there left should be the Main, and kill everything, the one on the right is only for the range.

    GFI protection is not required for K&T wiring, only if the two wire outlets are changed to three wire outlets, you do still have only two wire outlets, right?

    Three wire outlets can only be used on a two wire system if a GFI breaker or outlet is used to protect all the three wire outlets on a two wire system.

    Then each outlet is labeled with a "No Equipment Ground" label that is provided with the breaker or outlet. A GFI only provides ground fault protection and does not create n equipment ground, so the third prong, ground, is useless.
    kgdoube's Avatar
    kgdoube Posts: 11, Reputation: 1
    New Member
     
    #3

    Jun 16, 2006, 12:43 PM
    Yeah, only two wire outlets with those ground adapters for the units requiring it (I will be very excited when a storm surges our house and blows all the nice equipment).

    So what exactly would the range outlet be used for? Our problem is that we seem to be out of power to provide to the house, as now that summer time has come around it seems our fridge and freezer are working the circuit too hard. We put the deep freezer in last fall and everything was fine for the whole winter time, now that summer is coming around it seems that maybe the deep freezer may have problems. Three fuses have blown in the last few weeks. The furnace is on a 15 amp fuse, but we won't use the furnace during the summer. It would be nice to be able to use that source if it weren't for the fact that the line is hardwired into the furnace. Kind of wasn't to install a j-box there or something...
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #4

    Jun 17, 2006, 02:12 AM
    If you do not have a range, the pull out fuses mau be used for a dryer, water heater, or any other 240 volt load, or even may feed another fuse panel.

    If the freezer and refrig are on the same circuit, and each try to start at the same time this could trip that circuit's fuse.
    shunned's Avatar
    shunned Posts: 268, Reputation: 20
    Full Member
     
    #5

    Jun 17, 2006, 05:36 AM
    How many amps is this panel? Can/should this be upgraded to 100A?
    kgdoube's Avatar
    kgdoube Posts: 11, Reputation: 1
    New Member
     
    #6

    Jun 19, 2006, 05:49 AM
    The panel provides a total of 70 amps, but there is also an add-on box with another 45 or so for the dryer itself.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Breaker question? [ 6 Answers ]

How is everyone one doing? I am new to this site seems like there a lot of good information on hear. So I own my home. I was just curious is per say I have three 15amp breakers, Can I just swap those 15amp breakers with 20 amp breakers or do I have do do some wiring. Hence need an electrician? ...

Gfi breaker [ 1 Answers ]

I have an outdoor pond. I think that my electrical connection got wet and shorted out. My question is, I changed out all the receptacles on the gfi circuit and only two work. Is it possible that the breaker is bad and does not supply all of the circuits now??

Breaker [ 5 Answers ]

I have low voltage landscape lighting plugged into an outside outlet. The total watts is about 500 and I am using a 600 watt transformer. The outlet is a GFI outlet and has a dedicated 20 amp breaker. Nothing else is on this breaker. Sometimes the breaker will trip. I have replaced the...

15 amp breaker [ 5 Answers ]

Rewiring my kitchen, I have refrigerator, stove with electronic ignition, exhaust hood, and a microwave, and a duplex plug. Wondering if too much power for 15 amp breaker. Thanks for any info.

Question on 12 gauge w/ 15 amp breaker [ 2 Answers ]

Hello, Glad to have found this place. Just had a question regarding 12 gauge wiring. While I know it is unsafe to use 15 gauge for a 20 amp breaker, are there any safety concerns using 12 gauge wire on a 15 amp circuit breaker? Reason I ask is I had recessed lights put in my basement and had...


View more questions Search