    Basement subpanel.
    Thanks in advance for all help involved in my endeavors... First off let me start by saying this is an old home built in 1959 and has all fusible circuits.. The home was somewhat upgraded as far as I can tell in the 70`s with an exterior meter panel with breaker space for extra circuits,but by and large everything inside the existing home is in a loop with like 30 amp fuses(except the a/c,oven,waterheater, and dryer) and it`s scary how many existing receptacles and switches are run on each dedicated "fuseable circuit"... This is a large home... My question is that I`m wanting to install a subpanel in my basement from the meter box outside that has extra room for more breakers as well as a 50 amp breaker dedicated to a portable jacuzzi tub on the screened porch that will be done away with leaving the circuit for the basement and whatever else I need is where my query is leading... What amperage size subpanel box do I need for my basement applications?. My wife is turning our basement into the "workout/mediaroom,/dotcom biz she`s created... We needpower for 9-685 watt computers broken up into 3 circuits for 3 computers as well as needing receptacles all around the walls for everything else we need to plug in to the tune of probably another 2000 watts for my metalfab hobbies... Again... thanks... Bildr4u:D
    JackT's Avatar
    JackT Posts: 260, Reputation: 19
    Full Member
     
    #2

    Apr 11, 2007, 06:04 PM
    First thing you need to do is split up your 30 amp fuse circuits with smaller fuses. 30 amp fuses don't provide you with good protection and could be a fire hazard. Before you add a subpanel you need to know what size service you have feeding your meter pan. It won't help adding a subpanel if you only have an old 60 or 100 amp entrance coming into your house. The cable feeding your meter should have the size on it. #2 - 100 amp. 2/0 al. 150 amp. 4/0 al 200 amp. I hope this helps you out.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Subpanel in basement [ 1 Answers ]

I need three 20a circuits in basement. I planned to run #8 wire 50feet from main panel to a new sub panel in basement where I would have 3 20a breakers. Will this be OK or do I need #6 wire for the feed to the subpanel?

Need subpanel in basement [ 2 Answers ]

Hi, I am getting ready to finish my basement but my main panel is in my garage so I'm thinking it would make it easier for me if I install a subpanel in my basement. The main panel is 200 amp so I'd like to install a 100 amp subpanel. Is it okay to put in a 100 amp main breaker panel and feed...

Electrical Subpanel [ 1 Answers ]

I want to install a electrical subpanel(~50 amp) in my garage, if I do not feed the subpanel with a breaker from the main service of the house,would or could I tie into the main lugs of the main service to feed the subpanel? (Using the proper wire size) Would I have to use a ground rod for the...

Installing a Subpanel [ 3 Answers ]

I'm setting up a woodshop in my garage and want to install a subpanel to run my equipment off (it's going to be right next to the main). I'm starting from scratch, knowing extremely little about how to accomplish this. What sort of box do I need to buy, how do I size the breaker that will feed...

Adding subpanel [ 6 Answers ]

I have a 200A main panel in my garage and want to install a subpanel in my basement to feed 4 circuits (15 & 20 A). The best route I can find for the feeder wire is through the garage in conduit, then entering the basement through the concrete foundation. I have a couple of questions. 1. If I...