    Backfeed voltage on 3-way switches
    I am installing a new lighting circuit for 24v track lighting. The transformers are located in the middle of two 3-way switches. When the switch is on - either side - I get a reading on my multi meter of 124 volts. But when the switches are in the off position, I get a reading of 74 volts. When I hook up a test light fixture, it works fine.
    I have wired many of these in the past and have never had any problems, but this is the first time I have tested the voltage at the load/ light fixture. Is this normal? I have tested all the wires and have found no shorts. Both switches have been tested and replaced.
    constructionman
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #2

    Jul 28, 2007, 04:02 AM
    I would need to see a wiring diagram to understand what voltage is where. One thing confusing me, the transformer is in the middle of the two 3 way switches...

    Are the 3 way switches controlling the 120 volt or the 24 volts?

    By the way, what type of lighting do you have? Most low voltage lighting I am familiar with is 12 volts.

    # way switches do not have an on or off position. The switched leg from the switching is energized by which position both switches are in.

    Are you getting 124 volts at the light socket, that is suppose to be 24 volts?

    Where are you testing , at the light fixture?

    Really need to know more about what your doing and how this is connected to speculate.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Voltage drop [ 1 Answers ]

The Voltage will drop after 150 meter wire ,how to sole the problem . Thanks to all

Backfeed into a 200 amp box from a generator? [ 2 Answers ]

Hi... I have a regular house with a new 200 amp service, 220.. 30 amp service going to the garage... I have a 5500 watt generator... if I lose power at the house can I back fed the 200 amp box with the wire coming to the garage? Back fed into the 220 30 amp breaker from the garage , as long as I...

Voltage drop [ 4 Answers ]

A 300sq mm cable is to be laid for 600mtr. Distance. As the distance is large so there are considerable voltage drop at the receiving side. How can we cope up with this voltage drop at the receiving end? We want a constant voltage ofd 415 V at receiving end irrespective of input voltage? ...

Voltage drops [ 10 Answers ]

We have an ongoing problems with our house lights experiencing "drops" or "dimming". Our electricity provider has tested all external connections and installed a monitor, with no problems found. We had multiple electricians inspect the circuit box and all connections, with no problems found. ...

Voltage drop [ 2 Answers ]

How far can you run an electrical cord, that is plugged into a 20 amp circuit, and still run a circular saw? If the saw starts slowly, will that harm the saw?


View more questions Search