    Arc fault Breakers
    Do Arc Fault Breakers need to have a dedicated neutral in oder to work?
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #2

    Dec 4, 2007, 08:48 PM
    Yes, you wire just like GFI's. If bedroom was having ARC fault installed in older house. You may need to pull a neutral to where a multicircuit seperates(if 2 circuits are sharing the same neutral) So the neutral load is separate for that circuit only, not a circuit sharing that neutral.
    joedb4747's Avatar
    joedb4747 Posts: 2, Reputation: 1
    New Member
     
    #3

    Dec 4, 2007, 08:56 PM
    Quote Originally Posted by Stratmando
    Yes, you wire just like GFI's. If bedroom was having ARC fault installed in older house. You may need to pull a neutral to where a multicircuit seperates(if 2 circuits are sharing the same neutral) So the neutral load is seperate for that circuit only, not a circuit sharing that neutral.
    Thank for the answer!:)

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Arc fault breakers kick off [ 2 Answers ]

Our bedrooms all have arc fault breakers... when you plug a vacumn cleaner into the wall outlets in any of the bedrooms, the breakers kick out and have to be re-set... they are 15 amp breakers... what can I do?

Arch Fault Breakers [ 3 Answers ]

I installed AFCI breakers in a 100 amp panel. When the lights are turn on the breaker shut down the circuit. Everything is wired properly! Is there a special way to install AFCI breakers? Help Parcom

Recepticals and breakers [ 1 Answers ]

How many receptical can be put on a 20 amp breaker? Also would it be okay to put lampost lights on a breaker that services my basement? The total wattage would be 1055 watt. Thank you, Don

ARC fault breakers ? [ 4 Answers ]

I see where the 2005 NEC requires ARC fault breakers on all bedroom circuits,lighting and wall recepticals. It appears that this is for new construction. Would this also apply to rewiring an old house? Thanks in advance. Tom

Arc fault breakers [ 4 Answers ]

I am wiring bedrooms and I know that in California the outlets need to be on an arc fault breaker. 2 questions 1. would there be any problem in wiring a couple of recess lights in the bedrooms on the same circuit with the outlets? 2. There is an outlet in the hallway opposite and outlet in...