    Adding extra breakers to now full panel?
    My 100 amp service panel is full. I have no room to add any more circuits, what is needed to do so AS INEXPENSIVE as possible, thanks John :)
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #2

    Sep 11, 2007, 11:18 AM
    I made the mistake of cramming more in with tandem breakers 30 years ago. I am in the process of adding a sub panel. Small ones aren't that expensive. The first step is to read the label of your current box. It should give a maximum number of poles. Each single breaker is one, and the double pole ones are 2. Count what you have. If it is less than the maxim, you can replace existing breakers with tandem ones or half size ones, gaining one circuit for each one you replace. Go read your panel and count poles. If you need more help, post back. Mucking about in the main panel isn't the best place for a DIY, but you will get help here.

    In the 30 years I have had an over crowded panel, I haven't had any problems. However, it violates code. If you ever sell, you may be forced to bring the house up to code. May as well do it right now while you have tkrussell to help get it right.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #3

    Sep 11, 2007, 01:53 PM
    The general rule is the max branch circuit breakers allowed in any panelboard is 42.

    Different size, style, and manufacturers panels are limited to the total amount of branch circuit breaker allowed, for various reasons. The amount allowed , as Labman mentions, is listed on the label. This label will also state the model number of breaker allowed.

    It may be simple as Labman mentioned, (he has some experience with this) as pulling out one full size breaker and installing one tandem or two half size breakers. All depends on your panel.

    Many times the only remedy is to add a subpanel. This is not inexpensive, so may not suit your needs.

    Get back with the label info and we can go from there.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Main panel and sub panel breakers [ 1 Answers ]

I inspected a sub panel fed with a number 4 copper cable. The main panel breaker was a 90 amp breaker, but the sub panel breaker was a 100 amp breaker. Is this OK?

60 Amp Panel.how many breakers? [ 2 Answers ]

I recently bought a house with an old Federal Pacific Panel in it. (Yes yes I know, major fire hazard.) I was just wondering, it is rated as a 60 amp panel, does that mean that the sum of all the breakers must be less than 60 amps, or that no one breaker can exceed 60 amps?

Adding extra lights [ 4 Answers ]

I have wired up 5 extra down light in a circuit. When I turn them on, they dim and if I remove one they all go out. What amI doing wrong?

Adding an extra light [ 1 Answers ]

I have a light fitting with 3x100 watt spotlights on a dimmer switch and all worked well. I have picked up power from this light fitting and added another wall light (2x40 watt bulbs). Now, both sets of lights work, but the dimmer does not. The lights are either on or off when I turn the dimmer...

Adding Breakers to Existing Box [ 4 Answers ]

I'm finishing a basement in a large 8 year old home. We've added about 1500 sq feet in the basement and 5-6 new circuits. The breaker box, and a sub panel are full, with several mini breakers. We've been told that as part of the final electrical inspection a "load analysis" will be done....


View more questions Search