Ask Experts Questions for FREE Help !
Ask
    mr500's Avatar
    mr500 Posts: 181, Reputation: 8
    Junior Member
     
    #1

    Mar 24, 2008, 01:40 PM
    3 way switch
    Have a quick question on wiring 3 way switch. I want to come out of my panel into the overhead lights then down to the switch and of course on to the next 3-way. My question is can I run 12/2 from panel to the lights then down to the first switch THEN run 14/3 from this switch to the last 3 way. I know I CAN do it lol, just wanting to know does this throw up any red flags with me mixing the 12/2 and the 14/2 in the same run. Also it will fee out of a 15 amp circuit. There are about 4 fluorescent lights for this run.
    Mike
    stanfortyman's Avatar
    stanfortyman Posts: 5,598, Reputation: 279
    Electrical & Lighting Expert
     
    #2

    Mar 24, 2008, 02:02 PM
    You certainly can do that, but WHY bother??

    While it is not code required, I would definitely label the #12 in the panel "15A breaker ONLY".
    Someone is bound to come along later and say why did this guy use a 15A breaker on #12?
    THIS is one of the main reason I see NO reason to mix wire or to use an undersized breaker.
    mr500's Avatar
    mr500 Posts: 181, Reputation: 8
    Junior Member
     
    #3

    Mar 24, 2008, 02:06 PM
    Well I have a roll of 14/3 that was given to me, and instead of buying another 30 ft of wire with 3 conductors for the 3 way swtiches, I want to use the free stuff lol. If I had 12/3 I would use that but that's little more cost when I can get the 14/3 for free. That's the only reason.

    Its out on my shed, and I can LABEL it as you said.

    Thanks

    Mike
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #4

    Mar 24, 2008, 05:54 PM
    On the 3 way switching part, I would run power to 1 switch location, then run the lights to the other 3 way location.
    The power location, connect hot to common terminal of three way, red and black for travellers(between the 3 ways) the other three way will have the red and black from first three way plus the common(hot) that goes to the lights. The white joins in each box and connects to no switch.
    mr500's Avatar
    mr500 Posts: 181, Reputation: 8
    Junior Member
     
    #5

    Mar 25, 2008, 02:45 PM
    Gotcha.Thanks for all the help!! :D

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Change Pilot Light Switch with a Single-way Switch [ 1 Answers ]

It's worth noted that I am a complete novice, so please be patient with me. I want to replace an existing pilot light switch with a single-way lighted switch. The existing setup has four terminals (red wire, black wire, white wire, and ground wire). The red wire goes to the left, the black wire...

HEAT-OFF-COOL system switch - AUTO-ON fan switch [ 1 Answers ]

From an Email: ''Dear asklabman, I am a first time house ownere & having an issue with my Honeywell T8112 Programmable Thermostat. Thermostat has two switches for the fan - AUTO FAN & FAN ON switches and three switches for thes system, COOL, HEAT & System OFF modes. Yesterday we turned ON...

HEAT-OFF-COOL system switch - AUTO-ON fan switch. [ 2 Answers ]

Dear Gurus, I am a new house owner & not used to thermostats. We have Honeywell 8112D thermostat. We recently turned ON our Fan switch (in the thermostat). Now the fan is not turning off. It is continuously running even when the system is in OFF & Fan is in AUTO mode. We tried reducing the...

Wiring ceiling fan switch and light switch [ 1 Answers ]

I had to replace the flywheel on my Hunter ceiling fan and I had to remove the light kit that was attached. After I installed the flywheel, I forgot to mark the wires for re-connection. This is an older model fan. There are five wires coming from the fan motor--brown, blue, white, black and...

Converting pull switch lights to wall switch [ 3 Answers ]

I've been struggling finding the answer to this in books and online, it seems as if it should be an easy question and something that gets done all the time. Looking for some help. My basement has several rooms and all lights are wired "hot" with pull switches from each light receptacle. When the...


View more questions Search