    240 20 Amp double pole hookup
    So this site is great, thanks

    Ok my next question is if I have a 12-2 wire at the baseboard then I would hook-up the dual-pole 20Amp at the box with both the white and black into each of the breakers connection and of course the ground to ground, no nuetral, right?

    Steve
    Morrowrj's Avatar
    Morrowrj Posts: 345, Reputation: 22
    Full Member
     
    #2

    Dec 18, 2006, 05:59 PM
    Yes that is correct for 240 2-wire
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #3

    Dec 18, 2006, 07:31 PM
    Yeah, mark the ends of the white with black paint or tape.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #4

    Dec 18, 2006, 08:56 PM
    I assume the thermostat is built into the baseboard heat? Either way, even if it is a wall stat, it needs to be a double pole, be sure to read the instructions, most use two blacks for the Line, and two reds for the Load.

    And ground every green screw you find, and connect the ground at the panel along with any other bare or green wires.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Wiring Hot Tub and using a 50 Amp Double Pole GFCI Circiut Breaker [ 10 Answers ]

:confused: I keep getting the GFCI breaker tripping after wiring my hot tub. I wired 2 hot Red and Black to the proper terminals and the White to the neutral and the Bare Copper to the ground Post at the tub. I am using 6-3 w/G per instructions. Could the GFCI breaker be bad? When I wire...

20 amp double pole gfci [ 9 Answers ]

I am working on an addition and am installing a whirlpool tub. The tub requires 2 - 20 amp GFCI protect circuits: 1 for the pump and 1 for the heater. I ran 12/3 wire in the walls thinking I could have the BLACK wire go from 1 GFCI breaker to the pump outlet and the RED wire go from a 2nd GFCI...

Amp hookup [ 2 Answers ]

I have a new car with a good stereo system in it but it doesn't have the preamp outputs for the rca cables is there another way to hook my amp and subwoofers up to my stereo? If so how can go about doing it.

Installing double pole wall t-stat baseboard heater [ 2 Answers ]

I have a 220 baseboard heater, and it is on dedicated circuit. Heater works okay as I have run wires straight through and turned on circuit breaker and heater works. This is a Marley baseboard heater and wall double pole thermostat. Instructions with thermostat leave a lot to be desired. Actual...

Amp sub hookup [ 1 Answers ]

My sub is a kicker s15 15 inch 1500w solo baric. What wattage should I get for an amp?


View more questions Search