    200 amp service 4/0 ser cable in 2" conduit?
    What should I run from my disconnect switch to my panel box inside for my 200 amp service. I have 2" PVC ran from the disconnect to the panel. I thought about using 4/0 SER but then read somewhere that you are not suppose to put it in conduit because of possible temp problems? Is this correct or faulty information? Also if not SER 4/0 then what should I use?

    Thanks!
    Tev's Avatar
    Tev Posts: 232, Reputation: 20
    Full Member
     
    #2

    Feb 15, 2009, 07:19 PM

    SER can be used in conduit. In some cases, where subject to physical damage, it is required to be protected by conduit. I would use 2/0 copper or 4/0 aluminum THHN/THWN for your application.

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Service entrance cable size for 100 amp and 200 amp service. [ 16 Answers ]

I would like to know what size aluminum sec I would need for 100 or 200 amp service

Conduit size for MHF cable [ 5 Answers ]

Hi -- What is the proper conduit size for installing 4/0-4/0-4/0-2/0 Mobile Home Feeder cable? The meter box is on a pole about 25 feet from the house. The cable is rated for direct burial, but I think I should run the whole way in conduit because of the rocky soil.

Cable/conduit lubricant for pulling new cable? [ 1 Answers ]

What is recommended lubricant for pulling cable through conduit?

Can I run a electrical line in the same conduit as phone and cable? [ 9 Answers ]

Aloha All, I built a little 8'x12' office that is approximately 185ft from my main house. I was planning on running a electric, phone, and cable line in an underground conduit from my house to the office. Can I just use 20A romex for the electrical line that will be tapped off an exterior...

Do I need conduit to run a 220v cable through my cellar? [ 10 Answers ]

I'm running a 2-2/4 aluminum cable for a 220v circuit from my barn from the panel in my house. Once entering the home (from the 36" deep in-conduit run from the barn), I have to string the cable through the mechanical area (cellar) of the house, then through a center-home crawl space and then...


View more questions Search