New Member
|
|
Feb 21, 2008, 10:18 AM
|
|
Upgrading insulation in crawl space
I am starting this thread over since I asked a question on someone else's thread.
My existing situation is I have a tri level home. The crawl covers the first two floors (first floor being between 2-4 ft high, the 2nd floor between 8-9 ft high. The existing insulation is unfaced R-11, so the floors and family room downstaris are very cold in the winter. I want to upgrade the insulation to R-25. My question is can I get R-19 unfaced and install under the existing insulation or should I start over with R-25 faced? If I should start over, what should I do with the old insulation? It's dry as a bone. Could I put that under the new R-25, put it in the attic (attic seems to be fine but more never hurts) or just sell on craigslist or throw away? Thanks for any help.
|
|
 |
Home Improvement & Construction Expert
|
|
Feb 21, 2008, 10:36 AM
|
|
Yes you should be able to get an R-19 (or there abouts) and add to the existing insulation. You could probably use R-25 since the wires holding it up should not crush the R-25.
|
|
 |
New Member
|
|
Feb 21, 2008, 10:39 AM
|
|
So, it's not a problem to have unfaced against the floor? I've always heard you should have faced so you have the vapor barrier, but obviously it would be cheaper for me to get the R-19 unfaced if that would do the trick and get me to at least R-25.
|
|
 |
Home Improvement & Construction Expert
|
|
Feb 21, 2008, 11:05 AM
|
|
Well, that's what you have now, correct. There is not going to be much air movement through the subfflooring with the finished flooring on top. As explained in the other post it's the mixing of air masses that causes the condensation. Just didn't want you to trap moisture between two barriers.
|
|
 |
New Member
|
|
Feb 21, 2008, 11:11 AM
|
|
OK, thanks. I know this is a dumb question, but I'll clarify anyway, I want to take the wire hangers off the existing, put the new stuff under the existing, then put the wire hangers back up, right?
|
|
 |
Home Improvement & Construction Expert
|
|
Feb 21, 2008, 11:47 AM
|
|
I thought about that also, thinking that to existing insulation might fall in you face. Then I thought why remove the hangers, just leave them in place and use additional ones for the new.
|
|
 |
New Member
|
|
Feb 21, 2008, 12:23 PM
|
|
Wouldn't that cause air pockets between the 2?
|
|
 |
Home Improvement & Construction Expert
|
|
Feb 21, 2008, 01:09 PM
|
|
Maybe, but that's what insulations does, trap air. That air trapped in between the fibers is what gives it it's insulating qualities.
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Crawl space
[ 9 Answers ]
Hi! I'm from Ontario Canada.
I bought a house last July, it's approx. 55 ft by 40 ft with a crawl space of 16 inches in height.
There is 2 windows (screens) at each end of the 55 ft length and I was told by the owner to block the windows with styrofoam to keep it warm during the winter time so...
Heating a Crawl Space
[ 2 Answers ]
I have done the insulation and vapor barrier and dehumidification of my crawl space. It is still cold. Can I put a propane space heater in there to keep it warm?
Crawl space insulation
[ 2 Answers ]
I have an kitchen addition to my house that's about 2 years old. It is built over a 3.5' crawl space: vapor barrier & gravel floor, rigid blue board insulation on the interior of the foundation wall, batt insulation between the band boards. We have laminate flooring in the kitchen area and it...
Crawl space
[ 2 Answers ]
Hello there...
I've recently came upon a problem with condensation within the home (mini home). Each morning all the windows are really wet and the window sill is soaked! After going under the house I've noticed that things are pretty wet there too. Is there something you can get to...
Crawl space
[ 1 Answers ]
I need help on how much lime I need for crawl space.:o :o
View more questions
Search
|