    Why do I run out of hot water
    I have an 80 gal State Select Elect Hot water heater. After two showers the hot water runs out. The water pressure is 85 lbs. This has been a problem for quite some time. What is the most likely problem and how do I fix it?
    twinkiedooter's Avatar
    twinkiedooter Posts: 12,172, Reputation: 1054
    Uber Member
     
    #2

    Feb 14, 2009, 03:19 PM

    Probably one of your heating elements are burned out.
    anac0nda's Avatar
    anac0nda Posts: 3, Reputation: 1
    New Member
     
    #3

    Feb 14, 2009, 05:28 PM
    Turn up a little on the temperature controler on the Water heater or don't use too much of the hot water.
    That happends all the time when the hot water is over use. Same for me, when my wife and kids done taking a shower, all the hot water are gone and only warm water, but it takes a while to get the hot water back :)
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #4

    Feb 14, 2009, 05:35 PM
    You could have a broken dip tube in the heater. Do a Google on broken dip tubes
    Flying Blue Eagle's Avatar
    Flying Blue Eagle Posts: 2,056, Reputation: 225
    Ultra Member
     
    #5

    Feb 14, 2009, 07:11 PM

    jehoward - THE thermostat can be the trouble or it very well be the ( ANODE ROD) :: This is missed a lot of the time on repairing the hot water tank :: ANSWER - IN a area where the water has a lot of minrails in the water ,this rod will either rot off up close to the top in the still cool or cold water level. This rod unscrews out to be replaced or checked ;; NOTE- ( TURN OFF POWER TO THE TANK >DRAIN OFF SOME OF THE WATER <AND RELEASE PRESSURE:: DISCONNECT THE HOT WATER LINE ON TOP OF TANK< ::NOW UNSCREW THE ANODE ROD OUT OF THE TANK : THIS ROD IS NORMALLY LONG TO ALMOST REACH THE BOTTOM OF THE TANK.
    IF THE ROD IS BROKE OFF OR ROTTED OFF <THEN REPLACE WITH A NEW ROD< IF IT IS THE THERMOSTAT THEN YOU WILL HAVE TO DO A LITTLE MORE TESTING TO FIND OUT WHICH ONE IS BAD :: FIRST TRY THIS :: IF
    YOU FIND THE ROD IN GOOD CONDITION THEN, JUST COME BACK ON THIS POST AND HOLLER AND I OR ONE OF US WILL COME AND TRY TO HELP YOU OUUT ANOTHER WAY ::GOOD LUCK AND HAVE A GOOD DAY:: F.B.E.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Cold water coming out of hot water tap in bathroom but Really hot water in kitchen [ 7 Answers ]

Can anyone give me a reason as to why nearly completely cold water is coming out of my hot water tap in my bathroom but when I run the hot water tap in the kitchen the water is nearly boiling. The hot water and cold water taps are separate in the bathroom, where the kitchen has a handle which...

New hot water heater installed, but no hot water pressure. Plenty of cold water? [ 11 Answers ]

Hi, I own a small plumbing service and have a problem I've never encountered before. I installed a new top vented gas water heater for a customer. Turned the main back on, bled air out of the lines, etc. Problem is there is no hot water pressure throughout the house. Cold water pressure is fine....

Daylight basement water leak, cause by broken water pipe or saturated ground water? [ 1 Answers ]

I have a 6 units 3 stories with daylight basement apartment. Build in 1960. Just bought it few months ago. Last year the previous owner had a bad flood in the daylight basement after long period of rain. They cleaned out the area, remodel it. Good for few months, last couple of weeks rain long...


View more questions Search