Ask Experts Questions for FREE Help !
Ask
    long38's Avatar
    long38 Posts: 4, Reputation: 1
    New Member
     
    #1

    Oct 16, 2011, 11:09 AM
    Troubleshooting goodman furnace gmh80703ana?
    When I turn the furnace on the fan comes on. After a few seconds the ignitor starts glowing but the burner does not light. After 3 tries it then locks out with a lock out code.
    JonesHVAC's Avatar
    JonesHVAC Posts: 173, Reputation: 12
    Junior Member
     
    #2

    Oct 16, 2011, 11:25 AM
    Gas valve isn't opening up. Could be a bad transformer... you will need a multimeter and the know how to use it in order to solve your problem. If you can do this we should be able to talk you through it...
    long38's Avatar
    long38 Posts: 4, Reputation: 1
    New Member
     
    #3

    Oct 16, 2011, 11:47 AM
    I do have one and I have 120 volts between the black wire and white common. 24 volts between the red and blue
    JonesHVAC's Avatar
    JonesHVAC Posts: 173, Reputation: 12
    Junior Member
     
    #4

    Oct 16, 2011, 11:52 AM
    Ok, after the ignitor glows you should be able to hear the gas valve open and you should get 24-28v to the valve as well. Check this and let me know, thank you

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Goodman furnace troubleshooting [ 7 Answers ]

My goodman furnace/ heat pump will not turn on when I turn on at AC the unit outside will turn on but the blower will not. There trouble shooting light is not on.

Goodman furnace troubleshooting [ 3 Answers ]

Goodman 95% 2 stage furnace. LED code says pressure switch is stuck open. 1) Changed switch. 2) Jumped Limit switch. 3) Changed PCB. Same error code. 3 blinks "code says pressure switch is stuck open" Can You Guide me further

Goodman furnace troubleshooting [ 7 Answers ]

I put a new board in a GMP070 and the inducing fan motor kicks as normal, then the HSI starts to light but the whole board goes dead within 3 seconds.

Troubleshooting goodman furnace [ 1 Answers ]

The flame sensor keep burning out and only run for a couple of minute . Maybe the condensation trap is fully of dirt

Goodman furnace troubleshooting [ 2 Answers ]

I went away for a couple of days and returned to a cold house. I have a Goodman Model HCC075ND4R that has Electronic Ignition with Relay + VR80204 - S8600H Control. I can not get it to fully ignite. It tries to ignite over and over again. I see a single blue flame for a short time, but not main...


View more questions Search