Ask Experts Questions for FREE Help !
Ask
    patter8222's Avatar
    patter8222 Posts: 1, Reputation: 1
    New Member
     
    #1

    Apr 1, 2012, 01:41 PM
    Replace lennox 1dacb48-5p with r410a unit
    Can I replace lennox air r22 to r410a with any unit
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Apr 2, 2012, 05:47 AM
    No. The refrigerants are of different composition and use different lubricating oils. Not saying it cannot be done but the trouble is not worth it. The indoor coil for R-410A is also much larger to get the energy rate so it would be a looser all the way around. Get a matched coil for indoor and a quality unit for outdoor. Also replace the copper line set. NOTE: There are a few company's that are still making R-22 units for replacement only. They do not come charged with refrigerant. Contact a local qualified/knowledgeable contractor for more info.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Can I replace a hunter remote unit with a hampton bay unit? [ 1 Answers ]

A Hunter fan came with the house. It runs (ran) entirely off a remote control. It is an old house and there isn't a mechanical switch. After reading all of the terrible reviews for Hunter remote control units, I purchased a Hampton Bay remote control unit. After removing the fan from the ceiling, I...

I have a lennox outside a/c unit and a lennox g26 series furnace.Low hum no air/ht [ 4 Answers ]

Lennox Value Series... serial 5896G56798 M/N 10ACB365-5 P Central a/c unit and a Lennox G26 Series gas furnace both about 13 or 14 yrs old. Came home from vacation and turned A/C on (son tried earlier in the week) only a low hum whether on auto or fan or if we try heat(same thing, low hum)......

Trane R410A Unit qualities [ 1 Answers ]

:confused:We had outdoor condensing unit and TXV changed to a new R410A Refrigerant, what are the perks of this unit? I have heard of newer units being energy efficient, a cylce that runs at a lower speed when house is already cooled?

Replace existing A/C unit or upgrade to R410A-using unit? [ 3 Answers ]

Our A/C unit is slowly going on the fritz: struggling to provide cool air, now the 2nd time this summer. Technician came out to the house and suggested we remove the current unit, which uses R-22, and replace it with one that uses R410-A since the R-22 is getting forced out anyway. Now my...

Need Service Center for AC/Heat Unit with R410A [ 1 Answers ]

I am looking for a service center that can work on an ac/heat unit that requires R410A freon in it. I am in LaGrange Illinois. Thanks


View more questions Search