    No heat is produced
    I have a Kenmore mElite Smartheat 9 gas dryer.
    It was working no problem yesterday morning. In the afternoon, it still tumbled, but no heat was produced.
    drtom4444's Avatar
    drtom4444 Posts: 3,282, Reputation: 145
    Ultra Member
     
    #2

    Oct 14, 2012, 06:30 AM
    Here are some manuals: https://dl.dropbox.com/u/8010163/Whirlpool%20Dryers.zip
    These driers will do that when the lint builds up like concrete on the inside of the air ducts. The sensors get blocked from sensing when the dryer is dirty. Halfway cleaning it will not work because all it takes is one clogged up air passage or dirty sensor. You need to totally tear it down and scrape out and wash all of the parts except the motor, which you vacuum out. You can go to YouTube to see videos on how to take it apart, but do a very good job or it will fail again quickly. I would get a new belt and change it while you have it apart and get some white lithium grease and grease any bearings you find. You need to clean out a drier every two years, at least, according to the manual. You just unplug the wires from the sensors and remove ductwork that they are attached on and clean the entire thing with soap and water. Make sure you go all through the dryer and get all parts like the blower fan and housing (it has to be scrubbed and washed out), vacuum out motor well and clean exhaust. Mark all wires you unplug so you know where they go. This is an easier job than you would think. My sister does hers at least once a year since she has five children and the dryer gets a lot of use. Make sure to clean around all of the sensors, and you can check them with a meter and the chart in one of the manuals, too. See: Dryer vent cleaning prevents fires - YouTube and: Cleaning out a dryer with top lint cleanout - YouTube
    Cleaning out a dryer: By a woman 2 of 2 - YouTube You will find that one of the safeties is blown open, so you will need a meter to find which one is bad. These have to be replaced because they are non-resettable. You can buy ones that you can reset; they have a little red button on them that you push in to reset when you clean it out again.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

How many moles produced? [ 2 Answers ]

:confused: :confused: How many moles of Na3 C6 H5 O7 should have been produced from the moles of NaHCO3?

Where does heat energy come from and how is it produced [ 2 Answers ]

Where does heat energy come from and how is it produced

What gas is produced? [ 3 Answers ]

When hydrogen peroxide and manganese dioxide are mixed together, what gas is produced? When solid magnesium and hydrochloric acid are mixed together, what gas is produced? And lastly when calcium carbonate and hydrochloric acid are mixed together, what gas is produced? Thanks so much in...

Insufficient heat being produced by gas furnace [ 4 Answers ]

I have a gas furnace, located in the attic, and very warm air blows from a few vents in the ceiling and coolish air comes from other vents in the ceiling. I do not know what could be causing this problem. Please help. Judd


View more questions Search