    Maple chase thermostat Why AC is also working when you swith the heater ?
    I am having trouble in the heater. When you switch the heater on the AC is also working ? Any reason.
    drtom4444's Avatar
    drtom4444 Posts: 3,282, Reputation: 145
    Ultra Member
     
    #2

    Dec 2, 2011, 08:37 AM
    You have a short between "Y" (AC) and "W" (Heat)which usually are the yellow and white wire. An overload could have melted the insulation and shorted them out or the t-stat could be bad. Cut power off and take wires loose from both t-stat and at furnace connection and use an ohm meter to see if the wires are shorted. If not then check between W and Y on t-stat. If so, replace t-stat. If wire is shorted see if you have an extra wire and use it instead of Y or W. Y hooks to a wire going to outside condensing unit. DrTom4444

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

I have Maple Chase Thermostat that cuts the heater on then off about 2mins. Later. [ 0 Answers ]

The thermostate is about 17 year old. I can set it for the heater it will come on fire up then cut off about 2 minutes later and repeat this cycle. How do stop this so I can warm up my home. The furnace is fine it just does not stay on long enough heat the home. Help

Replacing maple chase thermostat with ritetemp thermostat model # 6030 [ 0 Answers ]

Replacing maple chase thermostat with ritetemp thermostat model # 6030

Maple chase thermostat heater works but at temp keeps turning off and on blowing cold [ 0 Answers ]

Maple chase thermostat heater works but at temp keeps turning off and on blowing cold


View more questions Search