    Lennox Heat Pump Troubles
    I have a Lennox heat pump unit and it will only run for about 3 minutes before the breaker on the unit trips,, What could cause this and how can it be fixed,,
    Rickey
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jan 13, 2009, 04:54 AM
    Breaker tired or worn allowing it to trip at a lower rate.

    Unit overcharged with refrigerant.

    Unit undercharged with refrigerant.

    Comperssor drawing to many amps causing the breaker to trip. Usually the compressor is defective.

    Bad or out of range run capacitor for the copmpressor.

    Most of this will need a professional to diagnose.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

20 yr old Lennox heat pump fan blows constantly in heat mode [ 5 Answers ]

20 year old Lennox heat pump - outside temps been 30's at night, 40's daytime UPDATE: I went outside and the unit is covered in frost on 3 sides! I've been reading on Google about frosted heat pump units and can't determine how to manually defrost it. Apparently, the auto defrost is not...

Lennox heat pump shorted out? [ 2 Answers ]

Hi! I hope someone can help me with this. Our Lennox unit is 13 years old and the circuit breaker for the compressor outside started going off. Every time I reset the breaker, it would blow again. I went out to the compressor, pulled the safety plug and then the circuit breaker would not blow. ...

Lennox Heat Pump System [ 1 Answers ]

Have a Lennox Heat Pump & Furnace. It is 7 years old and I have have 2 recent repairs on the system. This past August, the heat/cool valve was replaced because it was leaking freon. In November the control board in the furnace was replaced because the blower wouldn't come on to supply heat. Now,...

Lennox Heat Pump [ 1 Answers ]

I have a Lennox heat pump. I have measured 220VAC to the bottom of the compressor contactor. However, when I turn the thermostat to cool the blower fan comes on but the outside compressor is not energized. I can manually engage the contactor and the compressor and cooling fan come on. I can't...


View more questions Search