Ask Experts Questions for FREE Help !
Ask
    countyman_1's Avatar
    countyman_1 Posts: 1, Reputation: 1
    New Member
     
    #1

    Jun 14, 2012, 06:44 AM
    Hot Water Heater Pilot will not stay lit
    A.O. Smith - Promax, Model# GCV 40 00L010000, Serial# B05J023194. Pilot went out, followed all instructions. Everything seemed to work correctly, but pilot would not remain lit. Auto pilot ignitor worked, while holding down On/Off/Pilot knob, pilot lit, held down for 1 minute, On/Off/Pilot knob popped back up, but pilot would not stay lit. Tried several times.
    Handyman2007's Avatar
    Handyman2007 Posts: 988, Reputation: 73
    Senior Member
     
    #2

    Jun 14, 2012, 06:50 PM
    Quote Originally Posted by countyman_1 View Post
    A.O. Smith - Promax, Model# GCV 40 00L010000, Serial# B05J023194. Pilot went out, followed all instructions. Everything seemed to work correctly, but pilot would not remain lit. Auto pilot ignitor worked, while holding down On/Off/Pilot knob, pilot lit, held down for 1 minute, On/Off/Pilot knob popped back up, but pilot would not stay lit. Tried several times.
    The pilot has a flame detector on it that keeps the pilot lit once it sees a flame. Sounds like the flame detector is bad. Could also be the regulator,, that is where the flame detector connects. I would change the pilot assembly
    drtom4444's Avatar
    drtom4444 Posts: 3,282, Reputation: 145
    Ultra Member
     
    #3

    Jun 15, 2012, 08:38 AM
    That model has a thermocouple according to what I saw on the company web site; therefore, you need to replace the thermocouple and when you install the new one make sure that only 3/8" of tip is in the flame. No more than that or it will fail.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Hot water heater pilot will not stay lit? [ 1 Answers ]

The pilot light on my gas water heater will not stay lit. How can I test it?

Water heater pilot won't stay lit.. [ 4 Answers ]

Unit was new about 14 months ago, worked fine till recently. Whirlpool BFG1F404053NOV0751118163 Valve: Robert Shaw 64-LF8-376R110 RATSP1 Initially I was able to light the pilot again, and fire the heater and it would work, I believe up to temp, then hours later I'd notice the water going...

Blue Flame-Pilot will not stay lit-Hot Water Heater [ 7 Answers ]

My pilot light has a crisp blue flame when I light it and stays that color, but it will not stay lit. I have no problem lighting it, and then it takes off, but then it will go out after an hour or so. So, is this the thermocoupler?

Water heater pilot won't stay lit [ 2 Answers ]

Okay, last Friday BGE (Baltimore Gas and Electric) turned off the gas supply to a couple row houses on my block. They said water had gotten in the gas line and they were in the process of clearing it out. On Tuesday, when I was able to get my heat back (electric ignitor), the service guy tried to...