Ask Experts Questions for FREE Help !
Ask
    dtim01234's Avatar
    dtim01234 Posts: 3, Reputation: 1
    New Member
     
    #1

    Mar 26, 2011, 09:45 AM
    Gas dryer keeps shutting off and have to wait to restart
    Good morning:
    We have a 1999 Frigidaire LP gas front load dryer (model# FSG748GFS1) which started shutting off after 20--30 minutes. We can not get it to restart until it cools down for up to 30 minutes. After consulting with local appliance store, I replaced the motor ($124). Problem has not changed. Still shuts down with no restart.

    Gas solenoids are not reading within the ranges, however, the guy at appliance store didn't think that was problem. See attachment for solenoid readings.

    Any thoughts?
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #2

    Mar 26, 2011, 10:46 AM
    Most common problem is from plugged vent or vent fan motor. Make sure air flow is adequate or it will always overheat and trip the safety.
    dtim01234's Avatar
    dtim01234 Posts: 3, Reputation: 1
    New Member
     
    #3

    Mar 26, 2011, 11:49 AM
    I cleaned the vent out when I changed the motor. Also, the vent is only 8" long straight through wall with no elbows. Great airflow.

    Thanks
    drtom4444's Avatar
    drtom4444 Posts: 3,282, Reputation: 145
    Ultra Member
     
    #4

    Mar 27, 2011, 09:01 AM
    It sounds like the drier has hardened on deposits which requires it to be disassembled and scraped out then washed out to remove all deposits. You also have a t-stat that regulates the gas valve and a high limit switch which is set at a higher temp. If the high limit switch opens too soon it is usually because of deposits, but occasionally the limit is bad or the t-stat is not opening to regulate the temp. These are cheap and if the drier is very old I would just replace them. DrTom4444
    dtim01234's Avatar
    dtim01234 Posts: 3, Reputation: 1
    New Member
     
    #5

    Mar 31, 2011, 12:54 PM
    Thanks for the input. Where would the hardend deposits be? Inside the vent tubing? Burner?.
    Also, the gas solinoid readings are not within the ranges (+-). Would this be a part of the problem?
    Thanks
    drtom4444's Avatar
    drtom4444 Posts: 3,282, Reputation: 145
    Ultra Member
     
    #6

    Apr 1, 2011, 03:46 AM
    Comment on dtim01234's post
    You will find these deposits anywhere air flows. You disassemble the drier and clean out each piece to remove. They will cause a fire which is why the safeties shut the drier off. Most of the time you can fill a five-gallon bucket about 3/4 full with the deposits you remove. Vacuuming will not remove the deposits. Wash the parts out until clean. DrTom4444

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Kenmore Dryer won't restart [ 1 Answers ]

I have a Kenmore model 417.81142000 clothes dryer that would not restart yesterday after I removed a few items and attempted to resume operation. Today it started up just fine, but I'm concerned that something is soon to go out. Any thoughts as to what might be happening? I'd like to nip the...

Gas Furnace would not restart unless power is reset [ 5 Answers ]

Hello, I have a carrier furnace that works well once started for anywhere from 1 day to a week at a time and then seems to fail to restart. Once the power to it is reset (flipping the breaker off and back on) it seems to start fine and keeps on going stopping at the temp that is set and then...

Dryer keeps shutting off [ 2 Answers ]

I have a ge electric clothes dryer that runs for a few minutes then shuts off.I just replaced the start /stop switch,dryer seems to bog down some when starting, but then it runs OK ,could the belt possibly be loose. Thanks

Gas hot water tank will not restart [ 1 Answers ]

State select 40 galon hot water tank will not restart by itself. You have to manualy restart it then it works fine. When it stops working 2 lights come on on the temp setting panel. Any idea what's wrong?


View more questions Search