I'm installing the DSC1832 in my home. Here's how I wired:
1) Zone1= upstairs motion (4wire) red to Aux , blk to Aux-, yellow to Z1, Green to Com.
2) Zone2= downstairs motion (4wire) " " " " " " Z2 " " "
3) Zone3= upstairs smoke (4wire) red to Aux , blk to Aux-, yellow to Z3, Green to Com.
4) Zone4= upstairs smoke (4wire) "
3) Zone3= upstairs smoke (4wire) red to Aux , blk to Aux-, yellow to Z3, Green to Com.
4) Zone4= upstairs smoke (4wire) " " " " " " " Z4, " " "
5) Zone5= downstairs smoke (4wire) red to Aux , blk to Aux-, yellow to Z5, Green to Com.
6) Zone6= downstairs smoke (4wire) " Z4, " " " " " " " Z6, Green to Com.
7) Zone7= Temp. Alarm (4wire) red to Aux , blk to Auz-. Yellow to Z7, Green to Com.

I just can't seem to figure out the programming for this? Can anyone help?

Stratmando
Jan 19, 2012, 07:38 AM
In location 001 you need to program the 2 digit zone description for each zone in a 16 digit string of the 32 as this location now goes to 16 zones.
I don't see a door contact for entry. You can Program Motion as a perimiter and give it a delay to allow time to dissarm. If you had a Wireless fob for arming. Motions could be all Interior.
Can you get into Programming?
Also, If you use a PGM output, it will allow resetting of your smokes.